Understanding The Diagnostic Level - Pentair 1.0 Service Manual

Whole house acid neutralizing systems
Table of Contents

Advertisement

UNDERSTANDING THE DIAGNOSTIC LEVEL

To begin, verify that the control is in the Service Mode.
Time of Day
GL Remaining
• Press the UP ARROW and hold it for 5 seconds; the control will display:
Regen _ Days Ago
The control is now in the Diagnostic Level. Use the SCROLL BUTTON to advance to each diagnostic.
If no button is pressed within 5 minutes, the display will return to the Service Mode.
The following items are available in the Diagnostic Level (Read Only):
• Regen _ Days Ago: Displays how many days ago the unit last regenerated.
• In Srvc: Displays how many days the control has been in service.
• # of Regens: Displays the number of regenerations that have taken place since the control was first
installed.
• Tot Vol: Displays the total volume of water used since installation.
• Last Rgn @: Displays the amount of water used before the last regeneration.
• Flow Rate: Displays the current flow rate.
• Avg Vol: Displays the average daily water consumption.
• Capacity: The control is programmed for a volume setting. The display will read capacity
along with maximum water to be used before regeneration.
• Rsrv: Displays whether the control is programmed for a Fixed or Variable Reserve.
• Regen @: Displays the time of day the unit will regenerate.
• Override: Displays the override mode by reading "OFF" or the number of days programmed into the
control.
• Backwash: Displays the minutes of backwash programmed into the control.
• BRN/RNS: Displays the minutes of brine and slow rinse programmed into the control.
• FILL/RNS: Displays the minutes of fast rinse and brine refill programmed into the control.
• Units: English - US
• M P Resets: Displays how many times the control has lost power.
• Memory Reset: Displays how many times the control lost power long enough to lose the time of day.
• SP1Fc PlumbR21: Displays the current program.
To exit the Diagnostic Level, press the UP or DOWN ARROW at the EXIT display.