Breaker And Branch Circuit Setup - Tesla Gen 3 Wall Connector Manual

48a single phase
Table of Contents

Advertisement

POWER SHARING

Breaker and Branch Circuit Setup

Power sharing circuits may be installed in an electrical panel that supports other loads. If space is limited
or the main power supply is far from the Wall Connectors, installing a dedicated load center may be
prudent.
See below for examples of Wall Connector power sharing diagrams (one with sub-panel and one
without). Each individual Wall Connector in below examples is capable of providing 48 amps when it is
the only one in use. As more Wall Connectors begin plugging into vehicles, the system will automatically
distribute power based on the total power allocated to the site.
Power Sharing Setup with Sub-Panel
1. Wall Connector
2. 60 A branch circuit
3. 100 A sub-panel / feeder breaker
Power Sharing Setup Without Sub-Panel
1. Wall Connector
2. 60 A branch circuit
24