Ac Input Circuit Breaker; Dc Output Cable; Dc Output Circuit Breaker - Tesla TI150 Series User Manual

Battery charger/conditioner
Table of Contents

Advertisement

3
Features Overview
Figure 3.1.2
3.2 – AC Input Circuit Breaker
The AC Input Circuit Breaker located above the AC Input Receptacle (shown in Figure 3.1.2. Circled in
Yellow) protects the internal electrical circuit from damage caused by overload or short circuit. The AC
Input Circuit Breaker also acts as an "On/Off" switch for the Battery Charger/Conditioner.
3.3 – DC Output Cable
The DC Output Cable (shown in Figure 3.1.2 Circled in red) will provide either 14.25 Vdc or 28.5 Vdc
depending on the model, and comes with a quick disconnect for either ring terminals or alligator clamps.
When properly connected, the TI150 can deliver up to 20 amps at 14.25 Vdc or 10 amps at 28.5 Vdc. See
Section 4.3 for proper connecting procedures.
3.4 – DC Output Circuit Breaker
The DC Output Circuit Breaker (30 amp in 12V and 15 amp in 24V models) is located above the DC
Output Cable (See Figure 3.1.2 Circled in blue). When the circuit breaker has been tripped, the button
will pop out. In the event the breaker trips, verify that all connections are correct (polarity, line voltage,
etc.) and reset the breaker by pushing the switch to the "ON" position. The unit should provide dc power
automatically. If the breaker continues to trips, see Section 8 under Troubleshooting.