Hach Flo-Dar Sensor Basic User Manual page 25

Hide thumbs Also See for Flo-Dar Sensor:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
5.2.4 Attach the desiccant hub (FL900)
Attach the optional desiccant hub to the FL900 flow logger to give strain relief to the sensor cable
and the connector. Refer to
For the best performance, make sure to install the desiccant container vertically with the end cap
pointed down. Refer to
Figure 20 Attach the desiccant hub
1 End cap
Section 6 Operation
For sensors connected to an FL900 flow logger, connect a computer with
to the flow logger to configure, calibrate and collect data from the sensors. Refer to the
Desktop documentation to configure, calibrate and collect data from the sensor.
For sensors connected to an FL1500 flow logger, refer to the FL1500 flow logger documentation to
configure, calibrate and collect data from the sensors. As an alternative, connect a computer with
DATA Desktop software to the flow logger to configure, calibrate and collect data from the
FS
sensors. Refer to the
the sensor.
6.1 Install the software
Make sure that the latest version of the
Download the software from http://www.hachflow.com. Click Support, then select Software
Downloads>Hach FL Series Flow Logger.
Section 7 Maintenance
Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the
document.
Explosion hazard. When using the retrieval pole, make sure to connect the grounding strap to the
ground lug on the barrier. The sensor must also be connected to the barrier during maintenance
activities. This is to prevent ignition of explosive gases due to static discharge.
Figure
20.
Figure
20.
DATA Desktop documentation to configure, calibrate and collect data from
FS
DATA Desktop software is installed on the computer.
FS
D A N G E R
D A N G E R
DATA Desktop software
FS
DATA
FS
English 25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents