Description Of The Connections; Programming The Unit - DTS Alt 600 Installation Manual

Sectional door operator
Table of Contents

Advertisement

Terminals and Connections
1) GND & PB: Step by step command input (open stop
close) same as the step by step button on the transmitter.
= Push Button terminal
2) GND & PE = Photo Beam terminal.
3) 24V & GND & PB = Plug in receiver terminal.
To safeguard the opener and avoid damaging
components while wiring disconnect the unit from all
power when working on it.
Remember that there are specific, strict standards that
must be complied with in regard to both the safety of the
electrical systems and automatic doors.
Only qualified, trained personnel may carry out the
installation and subsequent maintenance.
Whoever installs and uses the Alt 600 sectional door
opener will be held responsible for any damage caused.
NOTE: Contact DTS Security technical department for
the wiring diagram for the above connections if uncertain
of the correct procedure.

Programming the Unit

The system must be checked and tested when
connections are completed.
4.1) Check that the chain support is halfway so that
movement is problem free both in opening and
closing.
Make sure that all the standards relative to the
automatic gates and doors category have been
observed.
4.2) Now carry out a test with the door disconnected
from the motor and open and close the door to
verify that the mechanical parts are all in good
working order and the door does not bind or jamb
in its tracks.
4.3) Power the unit. As soon as the unit is powered the
system displays a 7-segment LED number from 0-9,
and the lamp will turn on for 2 seconds.
Ground (GND)
Ground (GND)
Push Button (Trigger)
Push Button (Trigger)
If the LED display is upside-down, press the SET
button once, then the LED will display the number
in the correct direction. The system will remember
the display direction. It will display correctly next
time the power is turned back on.
If this is not the case, switch the power off
immediately and check connections carefully.
4.4) Check that all the safety devices on the unit are
working properly (emergency stop, photo beam, etc.).
This is one of the most important checks and must be
done with great care; in fact, the active safety of the
automatic door depends on the correct functioning of
the safety devices. The reversing sensitivity device is
of great help in minimising damage but only the
correct installation of the safety devices will make it
possible to stop the door before it can cause any
damage or injury to person and/or property.
4.5) It is now time to set the opening and closed
position.
-8-
24V DC
24V DC
Infra Red Beams (N/O)
Infra Red Beams (N/O)