Page 2
BASE PLATE MOUNTING INSTRUCTIONS 1. Assemble base plate by fastening M10x30 Hex set screws into base plate from under the base plate up and tightening into position. 2. Mount base plate with bolts 160mm from the centre of the gate track and centre of base plate a minimum of 250mm away from the gate opening.
Page 3
Limit switch actuator mounting instructions 1. Remove the screw attaching the nylon rack to the angle that is closest to the position of the spring on the motor when the gate is in the close and open position. 2. Fit limit switch actuators with screws provided onto the nylon rack. 3.
Page 4
Diagram to connect IR Beams to PCB Note: If sentry beams are fitted, then SBEAM, N/C on the PCB must be connected to N/O on the RX. Pedestrian Opening (Default 1 meter / 8 seconds auto close) Load setting To adjust the load turn the load pot to determine the load setting (Minimum, anticlockwise & Maximum, clockwise). PCB Control card.
Page 5
ON BOARD RECEIVER PROGRAMMING The onboard receiver is designed to work with most rolling code transmitters. PROGRAMMING A PROGRAMMING A TRANSMITTER (TX) FOR FULL TRANSMITTER FOR OPEN OPERATION – BT LRN PEDESTRIAN OPERATION - PD (Version 1.3) LRN (Version 1.3) Push the BT LRN button, the Push the PD LRN button, the RX led will go on.
Page 6
ELECTRONICS FEATURES: Standard mode. Easy motor direction change. (via jumper) Auto close facility. (Infra red beams must be fitted if auto close is activated). Standard Mode. (No function selected). When the gate is activated it will open and can be stopped in mid cycle by pressing the transmitter or manual push button.
TROUBLESHOOTING SYMPTOMS CAUSES ACTION When pressing the remote transmitter or Transmitter battery flat. Replace transmitter battery. manual push button the gate operator will not respond at all. Transmitter or manual push button is Check with supplier. physically damaged. Transmitter has not been programmed into Follow the receiver setup instructions.
Page 8
(Remote batteries are consumables and therefore carry NO warranty) • All goods are warranted to be free from faulty components and manufacture. • Faulty goods will be repaired or replaced at the sole discretion of DTS Security Products, free of charge.