DTS 412 Installation Manual

Sliding gate motor

Advertisement

DTS 412/512/624
SLIDING GATE MOTOR
INSTALLATION MANUAL
DTS SECURITY
P.O.BOX 3399
EDENVALE
1610
TELEPHONE 086 1000 387
Base plate-mounting instructions
Alberton
011 907 8846
Centurion 012 653 4434
Edenvale
011 524 0707
Pretoria
012 548 2336
West Rand 011 760 6564
E-EEEE
www.dtssecurity.co.za
1

Advertisement

Table of Contents
loading

Summary of Contents for DTS DTS 412

  • Page 1 DTS 412/512/624 SLIDING GATE MOTOR INSTALLATION MANUAL DTS SECURITY P.O.BOX 3399 EDENVALE 1610 TELEPHONE 086 1000 387 Base plate-mounting instructions Alberton 011 907 8846 Centurion 012 653 4434 Edenvale 011 524 0707 Pretoria 012 548 2336 West Rand 011 760 6564 E-EEEE www.dtssecurity.co.za...
  • Page 2: Base Plate Mounting Instructions

    300 to 400mm into the ground. 6. Fill area below and around the base plate with approximately 300x400x300 concrete to ensure that the motor will be secure. 7. NOTE - The DTS 412/624 motor must be fitted with a set of IR beams.
  • Page 3: Rack Mounting Instructions

    Gearbox mounting instructions 1. Fit gearbox over mounting bolts protruding from base plate. 2. Slide gate fully open and closed, insuring pinion gear has approximately 5mm clearance to gate at all times. 3. Fasten gearbox down firmly to base plate using M10 washers and nuts. Rack mounting instructions 1.
  • Page 4: Power Connections

    POWER CONNECTIONS Low voltage Plug in transformer. Connect 16V AC connectors on plug in transformer to 16V AC connectors on controller card. DO NOT CONNECT 220V DIRECTLY TO PCB Low voltage on board transformer – 220V at gate. Connect 220V AC to input side of 16V AC transformer (black & brown wires), connect output wires (red) to16V AC connectors on controller card.
  • Page 5 High access power supply unit – 220V at gate. Connect 220V AC to LEN (Live/Earth/Neutral) connecto r on side of power supply unit. Black lead from power supply unit gets connected to – ( neg.) PSU connection on Pcb. Red lead from power supply unit gets connected to + ( pos.) PSU connection on Pcb. DO NOT CONNECT 220V DIRECTLY TO PCB NOT USE POWER SUPPLY (PSU) UNIT AND LOW VOLTAGE TRANSFORMER (16V AC) TOGETHER.
  • Page 6 DO ALL RUNTIME AND TRANSMITTER PROGRAMMING BEFORE CONNECTING ANY ADDITIONAL INPUTS SUCH AS, –INTERCOM, BEAMS ETC. NOTE- IR beams must be fitted if DTS 412/624 motor is installed. DO NOT CONNECT 220V DIRECTLY TO PCB Dipswitch selections to activate a function.
  • Page 7: Programing

    PROGRAMING 1 – Run Time Setup (This will automatically happen when triggered after total power up or by following the steps below). • Gate approximately 1metre open • W ith all dipswitches OFF (excluding dipswitch 2 pending motor direction), press & release Bt/SET button.
  • Page 8: On Board Receiver Programing

    Load setting To adjust the load, turn the provided load pot very slowly to determine the load setting (Minimum- nticlockwise & Maximum clockwise). The control card will beep as you turn the pot (1 - 5 beeps). ON BOARD RECEIVER PROGRAMING The onboard receiver is designed to work with Sentry rolling code transmitters.
  • Page 9 ELECTRONICS FEATURES: Standard Easy motor direction chang Auto close facility (Infra re d beams must be fitted if a uto close is activated). Condominium / Free exit loop facility P.I.R.A.C (Passive Infra Re d Access Control) facility Slowdown (Ramp down) facility Standard Mode (No function selected) When the gate is activated it will open and can be stopped in mid cycle by pressing the transmitter or manual push button.
  • Page 10 Condominium/free exit loop (Dipswitch 4 On) When condominium/free exit loop is activated on the unit, the unit will not respond to an transmit ter or manual push button while in its opening cycle or open position. When the gate is on the open limit the unit will automatically wait the pre-programmed auto close time and then close (even if auto close function is not selected i.e.
  • Page 11: Pcb Control Card

    PCB Control card. For PCB identification 2 x Voltage regulators = 24V motor. 1 x Voltage regulator = 12V motor. NB – When connecting intercoms to the control card, please ensure that your intercom trigger output is potential free (ZERO voltage). If not, a gate relay module must be fitted.
  • Page 12: Troubleshooting

    TROUBLESHOOTING SYMPTOMS CAUSES ACTION When pressing the remote Transmitter battery flat. Replace transmitter battery. transmitter the gate operator will not respond at all Transmitter physically Check with supplier. damaged. Transmitter has not been Follow the receiver setup programmed into the receiver instructions.
  • Page 13 Before operating, the unit The primary supply has Check the household main gives two long beeps failed and the unit is running supply, the transformer or on battery reserve. PSU and all related cabling. The gate opens but will not The primary supply has failed Check the household main close...
  • Page 14 The unit beeps 3 times and The pedestrian (Pd) mode is Check with the other opens partially, beeps 3 being triggered. This is operators and check times and the closes. This constant if the sequence switching equipment / can sometimes continue keeps repeating.
  • Page 15: Manufacturer's Warranty

    • In the event of the goods being supplie d by dealer, merchant, agent or duly appointed installer of DTS Security Products, the claim must be directed to that supplier. • The carriage of goods is fo r the customer’s a...