SERVICE INSTRUCTIONS 834 Series Hydroelectric Instantaneous Gas Water Heaters TM081 Revision: AA Issued: Feb 2017 Issued: October 2016 834012N0 834012P0 834016N0 834016P0 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Adjusting the Gas Valve Gas Regulator ................. 49 COMPONENT REPLACEMENT PROCEDURES ............. 50 DOCUMENT REVISION HISTORY ................... 61 TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Do not modify this appliance. When conducting repairs, the gas train including injector sizes must not be altered in any way. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Not applicable due to not being connected to an electrical power supply. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 5
SV3 / MASV = Motor Adjustable Solenoid Valve (gas flow rate control) for main burner. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
DO NOT return the heater to service if any test/check result is outside specifications or if an unsafe condition exists. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
For more information refer to the Installation Instructions supplied with the heater. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
WIRING DIAGRAM – ALL MODELS TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Two Temperature Zones Using a Temperature Limiting Device TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 11
(hot tap turned off and then turned back on) at which time the heater will restart from step 1. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 12
> 0.5 µA. Normal flame generation is 2 ~ 10 µA (2 µA @ min fire, 10 µA @ max fire). TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Water Throttle Valve Flame Sensor Overheat Switch Ignition Rod Seasonal Adjustment Valve TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
This is not flow (or hot taps closed) voltage valves a fault TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
(refer to 'Frost Protection & Draining the Water Heater' procedure on page 7). TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Also refer to 'Ignition Module Flame Rectification Operation' on page 12. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 17
The rating label is located on the right side of the water heater. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Min and Max burner pressure adjustment dials. 3.7 VDC rechargeable battery. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
PRODUCT CHANGES There are no product changes at time of writing. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
2. Milky coloured water is generally air in suspension and will disperse of its own accord. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Green LED continuous flashing (≤ 3.1 VDC) Green LED will extinguish. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Refer to 'Operational & Fault Indication' on page 21 for fault indication fault finding chart indexes. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 23
Does overheat switch trip again? Replace overheat switch. (TEST 2) Heater tests ok. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 24
Fault rectified. persist? Replace gas valve assembly and reinstall original temperature controller. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 25
Correctly adjust ignition rod gap. ‘Component Adjustment correct? Procedures & Checks’ section. Replace ignition module. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 26
Clean or replace burner dirty or partially injectors. blocked? Clean or replace burner. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 27
Does red LED 7 flash Replace temperature controller. fault occur again? Heater tests ok. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 28
(faulty battery charging to go flat? function). Generator and battery charging functions ok. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 29
Unblock or replace blocked heat exchanger. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 30
/ flow sensor > 21 Hz? (TEST 14) assembly. Replace temperature controller. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 31
(TEST 10) Replace gas valve assembly. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 32
Heater working ok. Possible previous loss of gas supply or bad gas supply. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 33
Are burner min and Procedures & Checks’ section. max gas pressure settings correctly adjusted? TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 34
Clean or replace burner dirty or partially injectors. blocked? Clean or replace burner. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 35
DIP switches 7 & 8. decreased? Heater tests ok. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 36
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 37
Repair or replace heat NO – Leak is from heat exchanger exchanger. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 38
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
0.87 11.16 5.26 2.69 1.46 0.85 10.72 5.08 2.60 1.42 0.83 TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 40
The following result should be obtained: 8 ohms ± 10%. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 41
1.1 ~ 2.1 VDC. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 42
1.1 ~ 2.1 VDC. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 43
The following result should be obtained when water flow through the heater is > 3 L/m: 1.1 ~ 3.7 VDC. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 44
21 ~ 74 Hz (21 Hz @ 3 L/m, 74 Hz @ full flow rate). TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
3 MUST be set to OFF (down position) for the water heater to function correctly during normal operation. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
4. Gently disengage the front panel and pull downward to remove from the water heater. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 48
0.080 0.21 0.088 0.21 Max Setting (kPa) 0.72 1.85 0.74 1.85 TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
3 of this procedure to recheck the minimum burner gas pressure. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
DIP switches 1, 2 and 3 MUST be set to OFF (down position) for the water heater to function correctly during normal operation. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 51
11. Start heater and check for gas leaks using a soapy water solution. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 52
4. Reassemble in reverse order of above. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 53
15. Purge air from premises hot taps and check for water leaks. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 54
7. Using a shifting spanner, unscrew large hex head nut retaining burner manifold to gas valve. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 55
6. Start heater and check for water leaks. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 56
13. Start heater and check for water leaks. 14. Purge air from premises hot taps. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 57
8. Start heater and check for water leaks. 9. Purge air from premises hot taps. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 58
16. Start heater and check for water leaks. 17. Purge air from premises hot taps. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 59
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Page 60
3. Start heater and check for water leaks. 4. Purge air from premises hot taps. TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions REV: AA Issued: 22/02/17 This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.