Fault Finding Tests 8 ~ 10
Test 8
Using a multimeter set on the DC voltage
scale,
measure
terminal (orange wire) and the black earth
wire on the gas valve body. The following
result should be obtained during the
ignition period:
1.1 ~ 2.1 VDC.
Test 9
Using a multimeter set on the DC voltage
scale,
measure
terminal (green wire) and the black earth
wire on the gas valve body. The following
result should be obtained when the pilot
is alight:
1.1 ~ 2.1 VDC.
Test 10
Using a multimeter set on the DC voltage
scale, measure between SV3 wiring loom
plug green wire and the black earth wire on
the gas valve body. The following result
should be obtained when the pilot is
alight:
1.1 ~ 2.1 VDC.