Refer to the following pages for temperature controller information:
Wiring Diagram
Sequence of Operation (written explanation)
Operational Flow Chart
Operational & Fault Indication
DIP Switch Adjustments
Checking & Adjusting Burner Gas Pressure (Min & Max Dial Operation)
Ignition Module
The P700 ignition module provides a pulsed high voltage
to the ignition rod to create a spark for pilot ignition. The
ignition module also proves and supervises the pilot and
burner flame via the flame sensor.
When heating is required, the temperature controller
energises the ignition module which will then commence
the ignition sequence.
Note: The ignition rod and flame sensor leads are
supplied adhered to the ignition module and should not
be removed.
Refer to the following pages for ignition module information:
Wiring Diagram
Sequence of Operation (written explanation)
Ignition Module Flame Rectification Operation
Operational Flow Chart
PRODUCT CHANGES
There are no product changes at time of writing.
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions
REV: AA Issued: 22/02/17
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
Temperature Controller Information
Ignition Module Information
Page
8
10
14
21
45
47
Page
8
10
12
14
19