Rheem 834 Series Service Instructions Manual page 35

Hydroelectric instantaneous gas water heaters
Table of Contents

Advertisement

Fault Finding Chart 3
3
Water too hot
Do temp controller
LED's indicate a fault
condition?
NO
Is heater the correct
gas type for the
premises gas supply?
YES
Are all wiring plugs
and wiring connectors
firmly connected?
Refer to 'DIP Switch Adjustments'
YES
in the 'Component Adjustment
Procedures & Checks' section.
Are temp controller
DIP switches 1 ~ 6 in
the correct position?
Refer to 'Checking Inlet Gas Pressure'
YES
in the 'Component Adjustment
Procedures & Checks' section.
Is gas inlet pressure
correct?
YES
Is hot water outlet
temp sensor properly
installed?
YES
Is hot water outlet
temp sensor ok?
(TEST 1)
YES
Refer to 'Checking & Adjusting Burner Gas
Pressure' in the 'Component Adjustment
Are burner min and
max gas pressure
settings correctly
adjusted?
YES
Does temp at heater
hot water outlet =
setpoint temp ± 2°C?
YES
Refer to 'Adjusting the Setpoint
Temperature' in the 'Component
Adjustment Procedures &
Can setpoint
temperature be
decreased?
TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions
REV: AA Issued: 22/02/17
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
NG: 1.13 ~ 3.5 kPa
LPG: 2.75 ~ 3.5 kPa
Procedures & Checks' section.
Are main burner
NO
injectors correct size
for heater gas type?
Checks' section.
YES
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
Refer to fault finding chart for
the fault indication displayed.
Replace heater with a heater of
the correct gas type.
Firmly connect wiring
connector(s) and/or plug(s).
Ensure DIP switches 1, 2 and
3 are in the OFF position and
ensure DIP switches 4, 5 and 6
are in the correct position
according to heater model and
gas type.
Advise customer that gas supply
pressure is not within
specifications.
Ensure hot water outlet
temperature sensor is properly
installed in sensor well.
Replace hot water outlet
temperature sensor.
1.4
Replace main burner injectors
with injectors of the correct size.
Replace temperature controller.
decrease setpoint temperature
by adjusting DIP switches 7 & 8.
Heater tests ok.
35