CLM100 User's Manual
Sea Temperature
Outside Temperature
Inside Temperature
Engine Room Temperature
Main Cabin Temperature
Live Well Temperature
Bait Well Temperature
Refrigeration Temperature
Heating System Temperature
Dew Point Temperature
Wind Chill Temperature, Apparent
Wind Chill Temperature, Theoretical
Heat Index Temperature
Freezer Temperature
Exhaust Gas Temperature
16 User Defined temperature sources (User Defined 129 – User Defined 144)
4.11.2 Configuring Instance Number
Program this parameter to match the desired instance number of the temperature reading for
this channel. You can program this parameter to any value between 0 and 252.
4.11.3 Configuring Label
Program this parameter with a text string which identifies the particular parameter being
monitored by this channel. Maretron display products will display this label text when you are
selecting data to display.
4.11.4 Units, Range, and Resolution
Maretron display products and software support the following units for display of temperature,
with the range and resolution shown in the following table (NOTE: the resolution may be
further limited by the capabilities of the CLM100; please refer to section 1.7 for details).
Unit
Degrees Celsius
Degrees Fahrenheit
4.11.5 Configuring Temperature at 4mA
Program this parameter to match the reading of the temperature transducer when it is sourcing
a current of 4mA. You can determine this value by examining the specification of the
temperature transducer being used.
4.11.6 Configuring Temperature at 20mA
Program this parameter to match the reading of the temperature transducer when it is sourcing
a current of 20mA. You can determine this value by examining the specification of the
temperature transducer being used.
Page 20
Minimum Value
-273.15
-459.67
Maximum Value
16504.1
29739.3
Resolution
0.001
0.0018
Revision 1.0