Transducer Connections; Figure 2 - Nmea 2000 - Maretron CLM100 User Manual

Table of Contents

Advertisement

3.5.2 Transducer Connections

The CLM100 transducer connections are made by connecting to the 12-pin terminal strip on the
top of the unit. First, remove the four screws at the corners of the unit detaching the splash
guard from the unit. On the bottom of the splash guard, you will find a label detailing the wire
connection to pin number assignments, which are repeated in the table below.
Pin #
Signal Name
1
P0+
2
P0-
3
P1+
4
P1-
5
P2+
6
P2-
7
P3+
8
P3-
9
P4+
10
P4-
11
P5+
12
P5-
Please refer to Figure 3 for connecting the CLM100 to a 4-20mA current loop transducer. This
figure shows the connection of the 4-20mA transducer to channel 0 via the terminals named
P0+ and P0-. Connections to other channels are similar.
Revision 1.0
Figure 2 – NMEA 2000
Transducer 0
Transducer 1
Transducer 2
Transducer 3
Transducer 4
Transducer 5
®
Connector Face Views
Connection
(positive terminal)
(negative terminal)
(positive terminal)
(negative terminal)
(positive terminal)
(negative terminal)
(positive terminal)
(negative terminal)
(positive terminal)
(negative terminal)
(positive terminal)
(negative terminal)
Page 7