Configuring Channel Mode; Configuring A Channel In Dc Voltage Mode; Configuring Instance - Maretron CLM100 User Manual

Table of Contents

Advertisement

CLM100 User's Manual
The CLM100 can be configured using Maretron's DSM150 or DSM250 display, or with
Maretron's freely-available N2KAnalyzer software running on a Windows PC interfacing to the
NMEA 2000 network through a Maretron USB100 or IPG100 gateway. Please refer to the
appropriate configuration tool's user's manual for details on how to configure the CLM100 with
that product.

4.1 Configuring Channel Mode

The CLM100 has 6 individually configurable channels. Each channel can be programmed to
operate in one of the following modes:
 DC Voltage
 DC Current
 Flow Rate
 Distance
 Linear Velocity
 Linear Acceleration
 Angle
 Angular Velocity
 Angular Acceleration
 Temperature
 Humidity
 Resistance
 Strain Gauge
 Force (Load Cell)
 Pressure
 Decibels
 Rotational Rate (Shaft Speed, RPM)
 Disable – The channel is disabled and transmits no data over the NMEA 2000
network
The Disable mode requires no configuration. The following sections describe in detail the
configuration of a CLM100 channel for the other operating modes.

4.2 Configuring a Channel in DC Voltage Mode

The following sections describe the parameters that are available for configuration for a
channel which has been set to DC Voltage mode.

4.2.1 Configuring Instance

Program this parameter to match the desired instance of the DC voltage reading for this
channel. You can program this parameter to any value between 0 and 252.