CLM100
Current Loop Monitor
User's Manual
Revision 1.0
Copyright © 2015 Maretron, LLP All Rights Reserved
Maretron, LLP
rd
9014 N. 23
Ave #10
Phoenix, AZ 85021
http://www.maretron.com
Maretron Manual Part #: M003071
Revision 1.0
Page i

Advertisement

Table of Contents
loading

Summary of Contents for Maretron CLM100

  • Page 1 CLM100 Current Loop Monitor User’s Manual Revision 1.0 Copyright © 2015 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 Ave #10 Phoenix, AZ 85021 http://www.maretron.com Maretron Manual Part #: M003071 Revision 1.0 Page i...
  • Page 2 CLM100 User’s Manual Revision History Revision Description Original document Page ii Revision 1.0...
  • Page 3: Table Of Contents

    Parameters ........................... 4 Installation ..........................5 3.1 Unpacking the Box ......................5 3.2 Choosing a Mounting Location ..................5 3.3 Mounting the CLM100 ....................5 3.4 Mounting the Transducer ....................6 3.5 Connecting the CLM100 ....................6 ® 3.5.1 NMEA 2000 Connection ..................
  • Page 4 CLM100 User’s Manual 4.5.2 Configuring Label ....................14 4.5.3 Units, Range, and Resolution ................14 4.5.4 Configuring Distance at 4mA ................14 4.5.5 Configuring Distance at 20mA ................15 4.5.6 Configuring Data Damping Period ..............15 4.6 Configuring a Channel in Linear Velocity Mode ............15 4.6.1 Configuring Instance Number ................
  • Page 5 4.11.7 Configuring Data Damping Period ..............21 4.12 Configuring a Channel in Humidity Mode ............21 4.12.1 Configuring Source ................... 21 4.12.2 Configuring Instance Number ................21 4.12.3 Configuring Label ....................21 4.12.4 Units, Range, and Resolution ................21 4.12.5 Configuring Humidity at 4mA ................21 4.12.6 Configuring Humidity at 20mA ................
  • Page 6 Technical Support ......................30 Installation Template ......................31 10 Maretron (2 Year) Limited Warranty ................... 32 Table of Figures Figure 1 – Mounting the CLM100 ....................6 Figure 2 – NMEA 2000 ® Connector Face Views ............... 7 Figure 3 – 4-20mA Transducer Connection Diagram ..............8 Figure 4 –...
  • Page 7: General

    Another application example using the CLM100 is shaft speed monitoring. A commercially available 4-20mA rotational rate sensors is coupled to the shaft of interest and the CLM100 converts the transducer to an RPM that can display. And if you’re concerned about the force ®...
  • Page 8: Clm100 Accessories

    CLM100 to monitor pressures of gasoline, you must obtain a pressure transducer that is approved for use with gasoline. For other parameters, Maretron does not offer any accessories for the CLM100; however, the CLM100 is compatible with any transducer which offers an industry standard 4-20mA current loop interface and is able to operate with a current loop excitation voltage of 12-15VDC.
  • Page 9: Theory Of Operation

    The CLM100 can measure parameters with a resolution of approximately 0.33% of full scale. In many cases, the resolution to which the CLM100 can measure a parameter may be lower than the resolution at which NMEA 2000 represents the parameter. As an example, if a...
  • Page 10: Accuracy

    NMEA 2000 data types used to transmit the parameter value. For example, if you connected a DC voltage sensor with a range of 0-20VDC to the CLM100, the CLM100 could measure the parameter transmitted by the CLM100 to a resolution of 0.067V;...
  • Page 11: Installation

    Please consider the following when choosing a mounting location. 1. The CLM100 is waterproof, so it can be mounted in a damp or dry location. 2. The orientation is not important, so the CLM100 can be mounted on a horizontal deck, vertical bulkhead, or upside down if desired.
  • Page 12: Mounting The Transducer

    (or an NMEA 2000 compatible cable) by connecting the female end of the cable to the CLM100 (note the key on the male connector and keyway on the female connector). Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly. Connect the other end of the cable ®...
  • Page 13: Transducer Connections

    Transducer 5 (negative terminal) Please refer to Figure 3 for connecting the CLM100 to a 4-20mA current loop transducer. This figure shows the connection of the 4-20mA transducer to channel 0 via the terminals named P0+ and P0-. Connections to other channels are similar.
  • Page 14: Extension Of Transducer Wires

    20mA. The CLM100 supplies a minimum of 12V to each transducer at the maximum loop current of 20mA. In order to ensure that your transducer will work with extended wires, you should calculate the voltage drop across the extension wires.
  • Page 15: Configuring The Clm100

    First, calculate the resistance of the wire . Remember that the wire length needs to WIRE WIRE be multiplied by two, because the current needs to travel from the CLM100 to the transducer and then back again. 16.14Ω �� = 2 × ��...
  • Page 16: Configuring Channel Mode

    Maretron’s freely-available N2KAnalyzer software running on a Windows PC interfacing to the NMEA 2000 network through a Maretron USB100 or IPG100 gateway. Please refer to the appropriate configuration tool’s user’s manual for details on how to configure the CLM100 with that product.
  • Page 17: Configuring Label

    4.2.2 Configuring Label Program this parameter with a text string which identifies the particular parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 4.2.3 Units, Range, and Resolution...
  • Page 18: Configuring Instance

    Maretron display products and software support the following units for display of DC current, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 19: Configuring A Channel In Flow Rate Mode

    You can program this parameter to any value between 0 and 252. 4.4.3 Units, Range, and Resolution Maretron display products and software support the following units for display of flow rate, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100;...
  • Page 20: Configuring Flow Rate At 20Ma

    4.5.2 Configuring Label Program this parameter with a text string which identifies the particular parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 4.5.3 Units, Range, and Resolution...
  • Page 21: Configuring Distance At 20Ma

    Maretron display products and software support the following units for display of linear velocity, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 22: Configuring Linear Velocity At 20Ma

    Maretron display products and software support the following units for display of linear acceleration, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 23: Configuring Data Damping Period

    4.8.2 Configuring Label Program this parameter with a text string which identifies the particular parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 4.8.3 Units, Range, and Resolution...
  • Page 24: Configuring A Channel In Angular Velocity Mode

    4.9.2 Configuring Label Program this parameter with a text string which identifies the particular parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 4.9.3 Units, Range, and Resolution...
  • Page 25: Configuring Instance Number

    Maretron display products and software support the following units for display of angular acceleration, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 26: Configuring Instance Number

    Maretron display products and software support the following units for display of temperature, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 27: Configuring Data Damping Period

    Maretron display products and software support the following units for display of temperature, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 28: Configuring Humidity At 20Ma

    Maretron display products and software support the following units for display of resistance, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 29: Configuring Data Damping Period

    Maretron display products and software support the following units for display of resistance, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 30: Configuring A Channel In Force (Load Cell) Mode

    Maretron display products and software support the following units for display of resistance, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 31: Configuring Source

    4.16.3 Configuring Label Program this parameter with a text string which identifies the particular parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 4.16.4 Units, Range, and Resolution...
  • Page 32: Configuring Pressure At 20Ma

    4.17.2 Configuring Label Program this parameter with a text string which identifies the particular parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 4.17.3 Units, Range, and Resolution...
  • Page 33: Configuring Data Damping Period

    Maretron display products and software support the following units for display of rotational rate, with the range and resolution shown in the following table (NOTE: the resolution may be further limited by the capabilities of the CLM100; please refer to section 1.7 for details). Unit...
  • Page 34: Maintenance

     Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corrode the CLM100 enclosure or seals. Do not use any cleaners containing acetone, as they will deteriorate the plastic enclosure.
  • Page 35: Technical Specifications

    NMEA 2000 Parameter Group Numbers (PGNs) - See Appendix A for Details Description PGN # PGN Name Default Rate Periodic Data PGNs 65286 Fluid Flow Rate (Maretron Proprietary) 2 Times/Second 127751 DC Voltage/Current 0.67 Times/Second 130313 Humidity 0.5 Times/Second 130314 Actual Pressure 0.5 Times/Second...
  • Page 36: Technical Support

    Conducted, Radiated, Supply, and ESD per IEC 60945-10 Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 8 Technical Support If you require technical support for Maretron products, you can reach us in any of the following ways: Telephone: 1-866-550-9100...
  • Page 37: Installation Template

    9 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.0 Page 31...
  • Page 38: Maretron (2 Year) Limited Warranty

    10 Maretron (2 Year) Limited Warranty Maretron warrants the CLM100 to be free from defects in materials and workmanship for two (2) years from the date of original purchase. If within the applicable period any such products shall be proved to Maretron’s satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s option.
  • Page 39: Appendix A - Nmea 2000 Interfacing

    Oil, and Black Water. 7: Reserved bits – The CLM100 sets all bits in this field to a value of “1”. 8: Fluid Flow Rate – This field is used to indicate the rate of fluid flow in units of 1x10 /hour.
  • Page 40 4: Pressure – This field is used to indicate the pressure, whose source is specified in field 2, in units of 0.1 Pa. 5: Reserved bits – The CLM100 sets all bits in this field to a value of “1”. PGN 130316 –Temperature, Extended Range The CLM100 uses this PGN to provide a regular transmission of various temperatures.
  • Page 41 Field 1: Manufacturer Code – This field contains Maretron’s NMEA 2000® manufacturer code, which is 137. 2: Reserved – The CLM100 sets all bits in this field to a value of “1”. 3: Industry Group – This field contains the Marine industry group code, which is 4.