4.12.6 Configuring Humidity at 20mA

Program this parameter to match the reading of the Humidity transducer when it is sourcing a
current of 20mA. You can determine this value by examining the specification of the Humidity
transducer being used.

4.12.7 Configuring Data Damping Period

You can configure a damping parameter to smooth the Humidity readings or make them more
responsive. The data damping is configurable between 0.2-25.0 seconds with a resolution of
0.1 seconds. The default data damping for a channel in Humidity mode is 0.2 seconds.

4.13 Configuring a Channel in Resistance Mode

The following sections describe the parameters that are available for configuration for a
channel which has been set to resistance mode.

4.13.1 Configuring Instance Number

Program this parameter to match the desired instance number of the resistance reading for
this channel. You can program this parameter to any value between 0 and 252.

4.13.2 Configuring Label

Program this parameter with a text string which identifies the particular parameter being
monitored by this channel. Maretron display products will display this label text when you are
selecting data to display.

4.13.3 Units, Range, and Resolution

Maretron display products and software support the following units for display of resistance,
with the range and resolution shown in the following table (NOTE: the resolution may be
further limited by the capabilities of the CLM100; please refer to section 1.7 for details).
Unit
Ohms
KOhms

4.13.4 Configuring Resistance at 4mA

Program this parameter to match the reading of the resistance transducer when it is sourcing a
current of 4mA. You can determine this value by examining the specification of the resistance
transducer being used.

4.13.5 Configuring Resistance at 20mA

Program this parameter to match the reading of the resistance transducer when it is sourcing a
current of 20mA. You can determine this value by examining the specification of the resistance
transducer being used..
Page 22
Minimum Value
0
0
Maximum Value
4294967292
4294967
Resolution
1
0.001