Power Cut Detection And Detection Time Report - Sanav GX-101 Manual

Gps/gsm/gprs vehicle tracker
Table of Contents

Advertisement

4.19 Power Cut Detection And Detection Time Report

The user can use this command to set power cut detection and detection report interval GX-101 should reply.
Setup format:#「username」,「Password」,「Function Code」, 「intervals (sec)」, 「Total number of report」*
Example: #username,0000,20,60,0*
Note: When the total number of report is set "0", power cut detection will be disabled.
Text Keyed In SMS
#
username
0000
20
Interval(sec)
Total number of report
*
Table 4.19.1 The explanation of each segment.
Situation
Success when number of
report is 0
Success
Table 4.19.2 The reply when the setting successes
Description
Start sign.
Default ID of GX-101.
If you have changed the Username, please use the updated one.
Default password.
If you have changed the password, please use the updated one.
Mode 20 is to set power cut detection and report interval
Maximum 65000 seconds
1-9998 times; 9999
End sign
Description
username, setup ok. Device power cut notification is disabled
username, setup ok. Device power cut notification is enabled
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents