Feig Electronic OBID Classic-Pro Series Montage And Installation

Feig Electronic OBID Classic-Pro Series Montage And Installation

Rfid reader with ethernet interface
Hide thumbs Also See for OBID Classic-Pro Series:
Table of Contents

Advertisement

Available languages

Available languages

MONTAGE
®
OBID
classic-pro
INSTALLATION
ID CPR50.10-xE
(-E / -SE / -RE / -SRE)
RFID Reader for ISO/IEC14443-A & -B, NFC and ISO/IEC15693
with Ethernet Interface
(deutsch / english)
preliminary
public (B)
2009-10-07
M90701-1de-ID-B-FCC.doc

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Feig Electronic OBID Classic-Pro Series

  • Page 1 MONTAGE ® OBID classic-pro INSTALLATION ID CPR50.10-xE (-E / -SE / -RE / -SRE) RFID Reader for ISO/IEC14443-A & -B, NFC and ISO/IEC15693 with Ethernet Interface (deutsch / english) preliminary public (B) 2009-10-07 M90701-1de-ID-B-FCC.doc...
  • Page 2 ® OBID classic-pro Montage ID CPR50.10-E/-RE FEIG ELECTRONIC GmbH Seite 2 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 3 ® OBID classic-pro Montage ID CPR50.10-E/-RE deutsche Version ab Seite 4 english version from page 22 FEIG ELECTRONIC GmbH Seite 3 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 4 Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun- gen aus. FEIG ELECTRONIC GmbH übernimmt weder Gewähr für die einwandfreie Funktion in system- fremden Umgebungen, noch für die Funktion eines Gesamtsystems, welches die in diesem Dokument be- schriebenen Geräte enthält.
  • Page 5: Table Of Contents

    4.2.1. EMV-Beeinflussung über Zuleitungen .................17 4.2.2. EMV-Beeinflussung über magnetische Felder ............17 5. Technisch Daten ID CPR50.10-E/-RE 5.1. Zulassung ..........................19 5.2. Europa (CE)........................19 5.3. Declaration of Conformity for USA..................19 5.4. Declaration of Conformity for CANADA................20 5.5. Abmessungen........................21 FEIG ELECTRONIC GmbH Seite 5 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 6: Sicherheits- Und Warnhinweise - Vor Inbetriebnahme Unbedingt Lesen

    Obwohl dieses Gerät die zulässigen Grenzwerte für elektromagnetische Felder nicht ü- berschreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gerät und Ih- rem Herzschrittmacher einhalten und sich nicht für längere Zeit in unmittelbarer Nähe des Geräts bzw. der Antenne aufhalten. FEIG ELECTRONIC GmbH Seite 6 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 7: Lieferumfang

    Schneidschraube, Senkkopf 3,2 x 15 mm zur Montage von Gehäuseunterteil auf Aufputzadapter Schneidschraube, Senkkopf Schneidschrauben 3,2 x 25 mm zur Wandmontage Montageanleitung 2.1. Optionales Zubehör ID CPR.I/O-A: Extension Board mit einem Relais und zwei digitalen Eingängen FEIG ELECTRONIC GmbH Seite 7 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 8: Beschreibung Id Cpr50.10-E/-Re

    Alternativ kann der Reader ID CPR50.10-RE mit einem internen Relais verwendet werden. ID CPR.IO Door Contact ID CPR50.10-E Ethernet PoE Power Supply (IEEE802.3af) Ethernet Abbildung 1:Installation für ID CPR50.10-E mit optionalem I/O Extension Board ID CPR.I/O-A FEIG ELECTRONIC GmbH Seite 8 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 9: Montage Und Anschluss

    Der räumliche Abstand zu benachbarten Lesern gleicher Bauart sollte 30 cm nicht unter- schreiten. • Vor der endgültigen Installation sollte der geplante Installationsort auf seine Tauglichkeit geprüft werden. Abbildung 2: Aufputzadapter Abbildung 3: Unterputzgehäuse Montageausrichtung, Montageausrichtung, (⇑ TOP) nach oben (⇑ TOP) nach oben FEIG ELECTRONIC GmbH Seite 9 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 10 • Gehäuse von unten mit Schraube Torx 3x8 mm (Torx T10) verschließen. • Schutzfolie von Frontscheibe entfernen. Abbildung 4: Rückansicht mit eingerasteter Anschlussplatine (1) Abbildung 5: Gehäusedeckel stecken Abbildung 6: Gehäusedeckel öffnen FEIG ELECTRONIC GmbH Seite 10 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 11: Anschluss Des Adapter Board

    Tx D1+ Weiß/Grün Weiß/Orange Tx D1- Grün Orange Rx D2+ Weiß/Orange Weiß/Grün BI D3+ Blau Blau BI D3- Weiß/Blau Weiß/Blau Rx D2- Orange Grün BI D4+ Weiß/Braun Weiß/Braun BI D4- Braun Braun FEIG ELECTRONIC GmbH Seite 11 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 12: Anschluss X3 Für Spannungsversorgung Und I/O Modul

    DC – für ID CPR.I/O-A * Die Versorgung über ein externes Netzteil ist nicht notwendig wenn der Reader über ein PoE-Netzteil versorgt wird, in dem Fall bleiben die Anschlüsse VIN-Ext+ und GND-EXT- frei. FEIG ELECTRONIC GmbH Seite 12 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 13: Anschluss Über Poe Netzteil

    ID CPR50.10-E/-RE 4.1.3. Anschluss über PoE Netzteil In diesem Verdrahtungsbeispiel wird der Reader über ein PoE Netzteil mit Spannung versorgt. ID CPR.IO Door Contact ID CPR50.10-E Ethernet PoE Power Supply (IEEE802.3af) Ethernet FEIG ELECTRONIC GmbH Seite 13 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 14: Anschluss Einer Externe Spannungsversorgung

    • Versorgungsspannungen außerhalb der Spezifikation können zur Zerstörung des Gerä- tes führen. • Im Falle von getakteten Netzteilen auf ausreichende Filterung der Versorgungsspannung achten. • Störungen der Versorgungsspannung können sich negativ auf die Lese- und Schreib- reichweite der Module auswirken. FEIG ELECTRONIC GmbH Seite 14 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 15: Anschlüsse Des Externen I/O-Moduls (Id Cpr.i/O-A)

    über die Klemmen 7 [NO], 8 [COM] und 9 [NC]. 4.1.5.2. Digitale Eingänge (ID CPR.I/O-A) Die digitalen Eingänge [IN1] und [IN2]) dürfen nur gegen Ground, Klemme [GND] geschaltet wer- den. Eine Beschaltung mit Fremdspannung kann zur Zerstörung des Gerätes führen! FEIG ELECTRONIC GmbH Seite 15 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 16: Kommunikationsverbindung Zum Id Cpr50.10-E

    4.1.5.4. Spannungsversorgung des ID CPR.I/O-A Die Spannungsversorgung des externen I/O Moduls erfolgt ausschließlich über den Reader ID CPR50.10-E über die Anschlüsse VCC (+) und GND (-). Abbildung 10: Spannungsversorgung des ID CPR.I/O-A FEIG ELECTRONIC GmbH Seite 16 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 17: Montagehinweise

    Feldes. Magnetische Wechselfelder in der Nähe der Antenne können sich negativ auf die Funktion des Readers auswirken. Zu den Quellen solcher magnetischen Störfelder gehören zum Beispiel Spulen innerhalb eines primär oder sekundär getakteten Netzteils. FEIG ELECTRONIC GmbH Seite 17 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 18: Technisch Daten Id Cpr50.10-E/-Re

    ID CPR50.10-E Ethernet 10BASE-T/100BASE-TX Interface automatik MDI/MDI-X cross over correction TCP/IP protocol EEPROM für Konfigurationsparameter (1 Million Schreibzyklen) NFC: Type 1, Type 2 and Type 4 in read/write and NFC card emulation mode FEIG ELECTRONIC GmbH Seite 18 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 19: Zulassung

    - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FEIG ELECTRONIC GmbH Seite 19 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 20: Declaration Of Conformity For Canada

    Usually this is followed by the following RSS caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FEIG ELECTRONIC GmbH Seite 20 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 21: Abmessungen

    ID CPR50.10-E/-RE 5.5. Abmessungen 84,2 mm 77,7 mm 56,8 mm 60,0 mm 60,0 mm Abbildung 11: Unterputzgehäuse Abbildung 12: Aufputzadapter Befestigungsmasse Befestigungsmasse 84,2 mm 40 mm 22 mm 14,0 mm Abbildung 13: Gehäuseabmessungen FEIG ELECTRONIC GmbH Seite 21 von 39 M90701-1de-ID-B-FCC.doc...
  • Page 22 FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
  • Page 23 8.2.2. EMC effects from magnetic fields ................35 9. Technical Data of the Reader Family ID CPR50.10-E/-RE 9.1. Approval..........................37 9.2. Europe (CE)........................37 9.3. Declaration of Conformity for USA..................37 9.4. Declaration of Conformity for CANADA................38 9.5. Dimensions ........................39 FEIG ELECTRONIC GmbH Page 23 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 24: Safety Instructions / Warning - Read Before Start-Up

    25 cm between the device and your cardiac pace- maker and not stay in an immediate proximity of the device respective the antenna for some time. FEIG ELECTRONIC GmbH Page 24 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 25: System Delivery Contents

    Thread cutting screws 3,2 x 15 mm for mounting the surface adapter Thread cutting screw 3,2 x 25 mm for wall mounting Installation instruction 6.2. Optional Accessories ID CPR.I/O-A: Extension Board with one Relay and two digital Inputs. FEIG ELECTRONIC GmbH Page 25 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 26: Characterization Id Cpr50.10-E/-Re

    Optionally the reader ID CPR50.10-RE with one internal relay can be used. ID CPR.IO Door Contact ID CPR50.10-E Ethernet PoE Power Supply (IEEE802.3af) Ethernet Fig. 1: Installation diagram for ID CPR50.10-E with optional I/O extension board ID CPR.I/O-A FEIG ELECTRONIC GmbH Page 26 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 27: Installation

    Before any installation the intended position of the Reader should be tested for its suit- ability. Fig. 2 Surface adapter, Fig. 3 Concealed casing, Mounting direction, Mounting direction, (⇑ TOP) on top position (⇑ TOP) on top position FEIG ELECTRONIC GmbH Page 27 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 28 • Remove the protection foil from the front part. Fig. 4 Backside view with the fitted connection board (1) Fig. 5 Fitting of the housing cover Fig. 6 Opening of the housing cover FEIG ELECTRONIC GmbH Page 28 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 29: Connections

    Green Orange Rx D2+ Orange Striped Green striped BI D3+ Blue Blue BI D3- Blue Striped Blue Striped Rx D2- Orange Green BI D4+ Brown Striped Brown Striped BI D4- Brown Brown FEIG ELECTRONIC GmbH Page 29 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 30: Connection X3 For Power Supply And I/O Module

    * The power supply via an external power supply is not necessary if the reader is powered via PoE power supply. In that case the connection VIN-EXT+ and GND-EXT- are not used. FEIG ELECTRONIC GmbH Page 30 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 31: Connection With Poe Supply

    ® OBID classic-pro Installation ID CPR50.10-E/-RE 8.1.3. Connection with PoE Supply ID CPR.IO Door Contact ID CPR50.10-E Ethernet PoE Power Supply (IEEE802.3af) Ethernet FEIG ELECTRONIC GmbH Page 31 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 32: Connection With External Powered Supply

    • If switching power supplies are used with the module, be sure that there is adequate fil- tering. • Noise from the power supply can result in a reduction of the read/write range of the module. FEIG ELECTRONIC GmbH Page 32 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 33: Connections Of The Extension Io-Board (Id Cpr.i/O-A)

    7 [NO], 8 [COM] and 9 [NC]. 8.1.5.2. Digital inputs (ID CPR.I/O-A) The digital inputs [IN1] and [IN2] can only be connected to Ground, connector [GND]. Any connection to external voltage might damage the unit! FEIG ELECTRONIC GmbH Page 33 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 34: Communication Connection To The Reader Id Cpr50.10-E

    The power supply of the external I/O Module must be realized via the reader ID CPR50.10-E and the connection VCC (+) and GND (-). Fig. 10: Power supply of the ID CPR.I/O-A FEIG ELECTRONIC GmbH Page 34 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 35: Installation Notes

    Alternating magnetic fields in the vicinity of the antenna can have a negative influence on the reader function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. FEIG ELECTRONIC GmbH Page 35 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 36: Technical Data Of The Reader Family Id Cpr50.10-E/-Re

    Ethernet 10BASE-T/100BASE-TX Interface automatic MDI/MDI-X cross over correction TCP/IP protocol EEPROM for configuration parameter (1 million write cycles) NFC: Type 1, Type 2 and Type 4 in read/write and NFC card emulation mode FEIG ELECTRONIC GmbH Page 36 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 37: Approval

    - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FEIG ELECTRONIC GmbH Page 37 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 38: Declaration Of Conformity For Canada

    Usually this is followed by the following RSS caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FEIG ELECTRONIC GmbH Page 38 of 39 M90701-1de-ID-B-FCC.doc...
  • Page 39: Dimensions

    84,2 mm 77,7 mm 56,8 mm 60,0 mm 60,0 mm Fig. 11 Concealed casing Fig. 12 Surface adapter Fixing dimensions dimensions 84,2 mm 22 mm 40 mm 14,0 mm Fig. 13 Housing dimensions FEIG ELECTRONIC GmbH Page 39 of 39 M90701-1de-ID-B-FCC.doc...

Table of Contents