Water System - Saeco RI9722/11 Service Manual

Incanto s-class
Table of Contents

Advertisement

INCANTO S-CLASS

1. Water system

1.1. Water system (Incanto rondo)
Water tank
Wassertank
Wasserfilter
Water filter
Wasserfilter
Water filter
Flow meter
Flowmeter
Component
Water tank
Float
Water filter
Flow meter (turbine)
Pump
Safety valve
Boiler (flow heater)
Sensor (KTY)
Thermostat
Boiler pin (Valve plug)
HWS valve
Saeco International Group
Thermal sensor
Temp.sensor
KTY
KTY
Schwimmer
Float
Getriebevor
Gear resistor
-widerstand
Pumpe
Pump
Savety valve
Überdruckventil
Water supply
Water level monitoring
Water cleaned of solid matter (one or two depending)
Measure flow rate
Water flow/Pressure build-up
(13 to15 bar)
Protect boiler against overpressure (opens at 17 bar)
Heats water to approx. 84°C
(for brewing process)
Transmits current temperature value to electronic
system
Interrupts complete flow supply if overheating.
Opens when brewing unit is aligned with water circuit
to the unit itself.
For hot water and steam dispensing
REV.1 FEB.2005
4. FUNCTION/TIMING
Boiler
Durchlauferhitzer
2x Thermostat
2 Thermostate
Heizung
Heating
1090 W
1090W
Boiler pin
Ventilzapfen
HWS Valve
To brew unit
Brühgruppe
Function
HWD-Ventil
Hot water / steam
Heißwasser / Dampf
Page 1/9