Hot Water Dispensing - Saeco RI9722/11 Service Manual

Incanto s-class
Table of Contents

Advertisement

3. OPERATION

Hot water dispensing

14 Press hot water button.
15 Open HWS valve
16 Close HWS valve
17 Press hot water button.
Empty dregs drawer
Empty drip tray
Clean water tank.
Clean coffee bean container.
Clean the housing.
Rinse brewing unit
Clean brewing unit and lubricate
Clean filter
Descale
Water hardness
Very hard water (over 21ºdH)
Hard water
(15º-21ºdH)
Medium water
(15º-21ºdH)
Soft water
(4-7ºdH)
Soft water
(0-3ºdH)
Or when descaling requirement indicated.
Action
Need to descale
Keep the descaling button
pressed for about 5 sec.
Open HWS valve
Programme end
Close HWS valve
Rinse (fill tank 2x)
Install Aqua Prima filter.
Page 6/21
Immediately ready
Water removed
Water removal
complete
Steam mode
Cleaning
Storage capacity of 12 tablespoons (Reset - empty only when
indicated and with machine on)
After 12 servings
As required.
As required.
As required.
As required.
1 x per month
According to indicator.
Descaling frequency
Without Aqua Prima
About 2 - 4 weeks
About 4 - 6 weeks
About every 2 months
About every 3 months
About every 6 months
Descaling procedure
Comments
Remove the Aqua Prima filter
from the tank.
Fill water tank with commercial
descaler according to the
relevant instructions (Saeko
descaler recommended).
Place an appropriately sized
container under the HWS
nozzle.
Descaling programme is
activated.
The pipes are rinsed with
descaler at intervals. (Duration:
approx. 45 min)
When flow meter takes in air.
Descaling programme complete.
Open HWS valve
REV.1 FEB.2005
INCANTO S-CLASS
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Off
With Aqua Prima
About 4 - 6 weeks
About every 2 months
About every 3 months
About every 6 months
About every 6 months
Descale LED indicator
Light flashes
Light flashes
Light flashes
ON
ON
LED of all 5 buttons flash
Off
Off
Off
Saeco International Group

Advertisement

Table of Contents
loading

Table of Contents