INCANTO
Function/Standard
----HEATING----
SENSOR ADJUST.
96
NORMAL TEMP.
° C
84
HIGH TEMP.
° C
90
TEMP. OF 1st
COFFEE
° C
92
STEAM TEMP.
° C
125
TEMP. INCREASE
° C
10
GRINDS COUNTER
Number
GRINDS STOP
13
TOTAL WATER
(ml)
Number
Saeco International Group
Setting range
Increment
70- 130°C
70- 130°C
70- 130°C
70- 135°C
0-50°C
0-50
5-50
REV.5 FEB.2005
5. SERVICE PROGRAMME
Comments
To adjust processor tolerances.
If the temperature in test mode
with a set measuring resistance of
3246Ω exceeds or falls short of
the specified temperature value
(96°C) by more than 1°C, the
value indicated in test mode must
be applied to adjust the sensor.
No measuring resistance: Do not
change!
+/- 1
Normal temperature is used if not
more than 6 min. have elapsed
since last coffee dispensed.
+/- 1
If no coffee is dispensed for an
extended time (over 6 min.), the
next coffee will be heated to a
higher temperature to compensate
for cooling of the brewing unit
and the associated temperature
loss.
+/- 1
Used when dispensing the first
coffee after the machine has been
turned on, to compensate for the
high temperature loss due to the
cold brewing unit and water pipes.
+/-1
No function
+/-1
The boiler temperature is
increased by a set value shortly
before brewing in order to pre-
heat the boiler. and compensate
for the temperature drop during
the first water flow.
+/-1
Counts number of coffee cycles.
When this value reaches the
Grinds Stop value, "GRINDS
CONTAINER EMPTY" will be
displayed. (Reset by removing
dregs drawer for emptying - min.
6 sec.)
+/-1
Number of cycles until "EMPTY
GRINDS CONTAINER" is
displayed.
Total water flow volume (in ml) /
not resettable
Page 9/11