Components Supplied With The Unit For Site Fitting; Installation - Zip Aquapoint AP430S SmartEco Installation Instructions & User Manual

Direct unvented water heaters
Table of Contents

Advertisement

AQ105 kit is supplied with 30 to 50 litre models.
AQ108 kit is supplied with 80 to 100 litre models.
Both kits include:
Cold inlet assembly comprising pressure reducing valve with integral line strainer and
expansion relief valve with check valve, expansion vessel take off and balanced cold
water take off.
Expansion vessel and wall fixing bracket.
Wall locating bracket.
Tundish.
Cold inlet set
Expansion relief valve
Discharge to
tundish
Cold supply
to cylinder
Expansion vessel take off
Fig. 2
Internal check valve
The Aquapoint shall be installed as close as possible to the outlets.
When installing the Aquapoint in a room with a bathtub or shower, take into account the
requirements defined in IEC Standard 60364-7-701 (VDE 0100, Part 701).
The Aquapoint has to be fitted to the wall using appropriate wall screws with a minimum
diameter of 8mm.
A wall with a poor load-bearing capacity must be properly reinforced where the Aquapoint
will be installed.
The AP4 model may only be mounted vertically.
To facilitate future service interventions, you are advised to install the heater in accordance
with the installation measurements (see Fig. 3 and Fig. 7).
Installation instructions & user manual
T210023 v1.02 NOV 2018 - ZIP AP430S-AP4100S

Components supplied with the unit for site fitting

Installation

Tel: 0345 6 005 005 email: service@zipindustries .co.uk www.zipwater.co.uk
Pressure reducing valve
(inc. line strainer)
Cold mains in
Balanced cold take off
Technical support
9