Zip AQUAPOINT III Eco Installation Instructions & User Manual

Zip AQUAPOINT III Eco Installation Instructions & User Manual

Direct unvented water heaters

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS & USER MANUAL
ZIP
AQUAPOINT III Eco
Direct unvented water heaters.
MODEL NUMBER:
AP3/30e, AP3/50e, AP3/80e, AP3/100e
1
INSTALLATION INSTRUCTIONS & USER MANUAL
210001 V1.01 AUG 2017 - ZIP AP3/30e-100e
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK

Advertisement

Table of Contents
loading

Summary of Contents for Zip AQUAPOINT III Eco

  • Page 1 INSTALLATION INSTRUCTIONS & USER MANUAL AQUAPOINT III Eco Direct unvented water heaters. MODEL NUMBER: AP3/30e, AP3/50e, AP3/80e, AP3/100e INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 2: Table Of Contents

    To ensure you have the latest revision of this instruction manual, please visit www.zipwater.co.uk to download the latest copy. Please leave these instructions with the end user after installation. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 3: General Product Description

    GENERAL PRODUCT DESCRIPTION These instructions will guide you through the installation, maintenance and use of the Zip Aquapoint III Eco, however, if you require any further information please call Zip customer service on 0345 6 005 005. • The Zip Aquapoint III Eco is an unvented water heater designed for connection directly to incoming mains water supply and can serve one or more outlets using conventional taps.
  • Page 4: Technical Data

    (3) Measured at 20°C ambient temperature and 65°C water temperature in the heater (SIST EN 60379:2005 standard). INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 5: Dimensions

    PRODUCT DIMENSIONS Width Depth Height 1125 B - Outlet to mounting holes C- Mounting holes to top surface INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 6: Safety Information

    • Do not use the water heater if it is suspected of being frozen. Switch off the electrical INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 7: Cautions

    • When the appliance has been in use for some time, the fittings may be very hot. • The Zip Aquapoint III Eco is intended for connection to mains supply only. In any other case please contact Zip on 0345 6 005 005 for advice.
  • Page 8: Spare Parts

    Control panel AQ0317 Temperature & pressure relief valve AQ0315 Insulating bush AP3/30 Eco AP3/50 Eco - AP3/100 Eco INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 9: Components Supplied With The Unit For Site Fitting

    Cold Supply To Cylinder Cold Mains In Expansion Vessel Take Off Balanced Cold Take Off Internal Check Valve INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 10: Installation

    PIPE FITTING DIAGRAM Do not fit isolation (shut off) valve between cylinder and expansion valve. Zip recommend expansion vessels to be installed in line with the current HSE guidelines. Expansion vessels should be installed, in cool areas on cold flowing pipes,...
  • Page 11: Requirements

    An isolating valve must be fitted to the cold water supply to the inlet manifold. The Zip Aquapoint III Eco is designed for use with a supply pressure up to 1.2 MPa (12 bar). For supply pressures exceeding 1.2 MPa (12 bar) an additional pressure reducing valve must be fitted in the cold water supply to the unit.
  • Page 12: Discharge

    Note: It is not acceptable to discharge straight into a soil pipe. For guidance See G3 3.60. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 13 Plastic pipes may be of a different bore and resistance. Sizes and maximum lengths of plastic should be calculated using data prepared for the type of pipe being used. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 14: Positioning

    (see Technical data table, page 4) and capable of accepting suitable fixings. Position the Zip Aquapoint III Eco to allow for provision of the cold water supply, discharge fittings and pipework as well as access for future maintenance, repair of the unit or its replacement.
  • Page 15 11. Connect the hot water supply pipe to the outlet from the heater. 12. Connect the discharge pipe from the tundish. See discharge requirements, page 12 & 13. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 16: Electrical

    Ensure that the cover panel is replaced correctly and the retaining screws fitted before re-connecting the electrical supply. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 17: Commissioning & Operation

    Check the water temperature and re-check water connections adjusting as necessary. 14. Pass these instructions to the person responsible for the building management. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 18: Maintenance

    If power has been disconnected it is recommended that the unit is drained (see draining). 11. The Zip Aquapoint III Eco is fitted with a sacrificial anode to provide additional protection against corrosion. Gradual erosion of the sacrificial anode will occur depending upon local conditions which in extreme cases may cause rapid erosion of the anode resulting in particles being deposited as a residue.
  • Page 19: Schedule

    4. Disconnect the cold water inlet connection from the manifold assembly. 5. Disconnect the hot water supply pipe from the heater outlet. 6. Remove the heater. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 20: Fault Finding

    Faulty element. Check and replace as necessary. Thermostat failure. Check and replace as necessary. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 21: End Of Life Disposal

    In order to preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service for advice on 0345 6 005 005. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e...
  • Page 22: Warranty

    Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance.
  • Page 23 NOTES INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...
  • Page 24 Zip Water UK 14 Bertie Ward Way, Dereham, Norfolk NR19 1TE 0345 6 005 005 sales@zipindustries.co.uk www.zipwater.co.uk INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210001 V1.01 AUG 2017 - ZIP AP3/30e-100e WWW.ZIPWATER.CO.UK...

This manual is also suitable for:

Ap3/30eAp3/50eAp3/80eAp3/100e

Table of Contents