screens

sPeed eNTrY

It is required to define the speed in the Vibrio
MP. The autodetect appears on the first
screen. It works in the range of 3 - 200 Hz and
you can switch it off in setup. When you press
the middle button (USER) you can enter the
speed manually (by using the arrow buttons).
52

dC oFFseT

The measurement of the DC part in the signal
(gap) is displayed in Volts (range +/- 24 V).
www.adash.com

disPLACeMeNT iN 1-1 000 hz rANGe

Three display options are available to set in
setup:
RMS and TRUE 0-PEAK
RMS and TRUE PEAK-PEAK
TRUE 0-PEAK and TRUE PEAK-PEAK