Manually checking the cleaning device functions

General

Before starting the automatic cleaning process, the functions of the cleaning device
must be checked manually.
To ensure that the functions are checked properly, the welding torch must be in the
cleaning position.
Checking func-
tions manually
When the slot for the "Lifting device up/down", "Spray in parting agent" and "Clamp
gas nozzle/Cleaning motor on" screws is positioned horizontally, function is deac-
tivated.
1
2
The following must be checked when the functions are being performed:
-
-
1
3
Clamp gas nozzle/cleaning motor on
48
NOTE!
NOTE!
NOTE!
Disconnect the cleaning device from the robot control
Establish a compressed air supply to the cleaning device
function of the gas nozzle clamping device (gas nozzle clamping device extends/re-
tracts)
function of the cleaning motor (cleaning motor OFF/ON)
2
4
2
1
0
1
Deactivating the functions