Locking/Unlocking The Fill-Level Control Sensor; Electrical Connection - Fronius Robacta Reamer V Twin Manual

Welding torch cleaning
Hide thumbs Also See for Robacta Reamer V Twin:
Table of Contents

Advertisement

Locking/unlock-
ing the fill-level
control sensor
Locking the fill-level control sensor:
1
Unlocking the fill-level control sensor:
1
Electrical connec-
tion
10 s
Simultaneously press the "OUT OFF" and "OUT ON" buttons for at least 10 seconds
-
The LED status changes briefly
-
if the LED lights up when locking, it will go out briefly after locking
-
if the LED does not light up when locking, it will come on briefly after locking
Simultaneously press the "OUT OFF" and "OUT ON" buttons for at least 10 seconds
-
The LED status changes briefly
-
if the LED lights up when unlocking, it will go out briefly after unlocking
-
if the LED does not light up when unlocking, it will come on briefly after un-
locking
1
1
L-
4
4
3
3
L+
Press the "OUT OFF" button for at
2
least 6 seconds
-
The sensor LED flashes slowly at
first, then more rapidly after 6 se-
conds
-
After releasing the "OUT OFF"
> 6 s
button the LED goes out - the sen-
sor has detected a high fluid level
NOTE!
It is possible to lock the fill-level control
sensor to prevent it from being adjusted
accidentally.
10 s
Wire colours:
1.
brown
L-
4
2
3.
blue
1
3
4.
black
L+
47