Before commissioning

Proper use

The cleaning device is to be used exclusively for cleaning Fronius robot welding torches,
especially the gas nozzle and its interior, in automatic mode and within the scope of the
technical data. Any use above and beyond this purpose is deemed improper. The manu-
facturer shall not be held liable for any damage arising from such usage.
Proper use includes:
-
-
-
Operators, main-
NOTE!
tenance person-
nel
The device must only be used by one person at a time.
It is also necessary to ensure that no one else is within the working area of the device when
the device is being used.
NOTE!
The device must only be serviced by one person at a time.
It is also necessary to ensure that no one else is within the working area of the device when
the device is being serviced.

Setup regulations

The cleaning device is tested to IP 20, meaning:
-
-
The device must not be set up and operated outdoors. The built in electrical parts must be
protected from direct wetting.
Compressed air
To ensure that the cleaning device functions correctly, the following compressed air supply
supply specifica-
specifications must be met:
tions
-
-
Measures for the
If untrained operators have access to the device, its compressed air supply must be dis-
safe operation of
connected for the duration of work in accordance with 'Performance Level d' of the ISO
the device with
13849-1 standard.
untrained person-
nel
To ensure that the compressed air supply is interrupted as required, MS6-SV pressure
build-up and pressure relief valves from FESTO are recommended.
carefully reading these operating instructions
following all the instructions and safety rules in these operating instructions
performing all stipulated inspection and maintenance work
protection against penetration by solid foreign bodies with diameters > 12.5 mm (0.49
in.)
no protection against penetrating water
Establish compressed air supply using a pressure limiter and compressed air filter
Provide compressed air quality conforming to ISO 8573-1:2001, class 7 4 3, instru-
ment air
Solid particle concentration  10 mg/m
-
Vapour pressure dew point  + 3°C
-
Oil concentration  1 mg/m
-
3
3
33