Technical Specification - Elcometer 701 Operating Instructions Manual

Live cable locator & cable avoidance tool
Table of Contents

Advertisement

T
ECHNICAL SPECIFICATION

10 TECHNICAL SPECIFICATION

10.1 Elcometer 701 Receiver (Rx)
Frequency range
Range 1: radio
Range 2: power grid
Range 3: transmitter
Sensitivity (at a depth of 1 m)
Range 1: radio
Range 2: power network
Range 3: transmitter
Dynamic response range
Range 1: radio
Range 2: power network
Range 3: transmitter
Depth determination
Depth range
Resolution
Accuracy
Range 1: radio
Range 2: power network
Range 3: transmitter
Power supply
Operating time
Temperature range (in accordance with EN 60068-1)
Operation
Storage
Weight
Dimensions (W x H x D)
Type of protection (in accordance with EN 60529)
Dust and water protected
26
R
15 kHz to 23 kHz
50 Hz / 60 Hz (switchable)
(optionally 100 Hz - contact Elcometer)
32.768 kHz
>20 µA
>7 mA
>5 µA
120 dB
135 dB
120 dB
0.1 m to 5 m (4 in to 16 ft)
0.1 m
±20%
±20%
±5% (to 2 m) ±20% (between 2 m and 5 m)
10 x IEC R6 / AA cell / Mignon
40 hours (intermittent use with alkaline batteries, 20°C)
-20°C to +55°C
-30°C to +70°C
2.5 kg
99 mm x 660 mm x 252 mm
IP 67 from the lower edge of the receiver up to the lower edge
of the battery compartment, and IP 56 for all parts above this.

Advertisement

Table of Contents
loading

Table of Contents