9.10

General settings

General settings for the tool management user interface
are stored in the <SETTINGS> tag.
Entries
ReactivateWithMagPos
MagazineMoveMessage
CreateNewToolDialog
MagazineSelectionDialog
Example
HMI sl (IM9)
Commissioning Manual, 07/2007, 6FC5397-1DP10-2BA0
Meaning
Refers to the "Reactivate" function
true - Reactivate a locked magazine with positioning of the magazine
false - Reactivate without positioning of the magazine
Refers to the message output while the magazine is moving.
true - "Magazine movement running" or "Magazine movement ended"
message is displayed.
false - Message is not displayed.
Refers to the "New tool" function.
true - The "New tool" window appears. In this window, you can specify
the type of magazine location and the size of the tool before actually
creating the tool.
false - The "New tool" window does not appear. Once the name has
been entered, the tool will be created directly in the tool list.
Refers to the "Magazine selection" function
true - A dialog box displaying the buffer, magazine and NC memory is
displayed. A check mark can be added to or removed from each of
these elements to indicate whether that element appears in the list
display. The "Go to..." softkey can be used to select an element directly
in the list display.
false - No dialog box for magazine selection. The system toggles
between the buffer, the magazines and the NC memory.
If there is no MagazineSelectionDialog entry in the <Settings> tag, the
dialog box is automatically displayed with more than one magazine
(excluding the system magazine) when magazine configuration is
taking place. If there is only one magazine, the toggle function is used.
Configuring tool management
9.10 General settings
83