Victron energy MultiPlus 12/3000/120 – 50 Manual page 38

Extremely powerful sine inverter, battery charger and automatic switch in a compact casing
Table of Contents

Advertisement

Step 2: Exemplary settings for stand-alone mode
Example 1 is the factory setting.
Note: since factory settings are entered by computer, all DIP switches of a new product are set to
'off' and do not reflect the actual settings in the microprocessor.
DS-8 Ch. voltage
DS-7 Ch. voltage
DS-6 Absorpt. time
DS-5 Adaptive ch.
DS-4 Dyn. Curr. limit
DS-3 UPS function:
DS-2 Voltage
DS-1 Frequency
Step 2
Example 1 (factory setting):
8, 7 GEL 14,4V
6 Absorption time: 8 hours
5 Adaptive charging: on
4 Dynamic current limit: off
3 UPS function: on
2 Voltage: 120V
1 Frequency: 60Hz
To store the settings after the required values have been set: press the 'Down' button
for 2 seconds (lower button to the right of the DIP switches). The temperature and
low-battery LED's will flash to indicate acceptance of the settings.
You can then leave the DIP switches in the selected positions, so that the 'other
settings' can always be recovered.
34
off
DS-8
on
DS-7
on
DS-6
on
on
DS-5
on
off
DS-4
on
DS-3
on
DS-2
on
off
DS-1
on
Step 2
Example 2:
8, 7 OPzV 14,1V
6 Abs. time: 8 h
5 Adaptive ch.: on
4 Dyn. Curr. limit: off
3 UPS function: off
2 Voltage: 120V
1 Frequency: 50Hz
off
DS-8
on
off
DS-7
DS-6
on
DS-5
on
off
DS-4
on
off
DS-3
DS-2
DS-1
on
Step 2
Example 3:
8, 7 AGM 14,7V
6 Abs. time: 8 h
5 Adaptive ch: on
4 Dyn. Curr. limit: on
3 UPS function: off
2 Voltage: 115V
1 Frequency: 50Hz
DS-8
on
off
DS-7
on
DS-6
DS-5
DS-4
off
DS-3
on
off
DS-2
DS-1
Step 2
Example 4:
8, 7 Tub.-plate 15V
6 Abs. time: 4 h
5 Fixed abs. time
4 Dyn. Curr. limit: off
3 UPS function: on
2 Voltage: 115V
1 Frequency: 60Hz
off
off
off
off
off