H'87:Configuration 8
H'C:Listen-Only Connection Number
When Instance = 0, the Class Attributes are listed below.
Class
Name
Attribute
H'01
Revision
H'02
Max Instance
When Instance = 64–87, the Instance Attributes are listed below. (Length of input and output is editable. The
maximum length is 250 words; supports only even bytes)
Connection No.
Connection 1
Connection 2
Connection 3
Connection 4
Connection 5
Connection 6
C h a p t e r 9 E t h e r n e t S p e c i f i c a t i o n a n d O p e r a t i o n
Access
Data Type
Rule
Get
UINT
Get
UINT
I/O Message Connection
Function
Instance Attribute
Input (TO)
0x65
Output (OT)
0x64
Configuration
0x80
Input (TO)
0x67
Output (OT)
0x66
Configuration
0x81
Input (TO)
0x69
Output (OT)
0x68
Configuration
0x82
Input (TO)
0x6B
Output (OT)
0x6A
Configuration
0x83
Input (TO)
0x6D
Output (OT)
0x6C
Configuration
0x84
Input (TO)
0x6F
Output (OT)
0x6E
Values
Description
H'2
Revision of this object
The maximum number of
H'C7
instances
Length
D1000~D1099
D0~D99
Refer to the table below
D1100~D1199
D100~D199
Refer to the table below
D1200~D1299
D200~D299
Refer to the table below
D1300~D1399
D300~D399
Refer to the table below
D1400~D1499
D400~D499
Refer to the table below
D1500~D1599
D500~D599
9_
9 - 7 3