Test Menu (TEST)

The Test menu allows you to manually home the fixture, turn the lamp on or off, store new boot
code information, and perform fixture self tests to determine the origin of mechanical problems.

Homing the Fixture (HOME)

This menu item allows you to manually home the fixture. To remotely home the fixture using a
DMX console, see Control Parameter on page 53. To manually home the fixture:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the TEST menu. Press <Enter> to select.
3. Scroll to the HOME option (this will be the first option displayed).
4. Press <Enter>. The LED will alternately display RST and HOME while the fixture
homes.

Turning the Lamp On or Off (LAMP)

This menu item allows you to manually strike or extinguish the lamp. To remotely strike or
extinguish the lamp using a DMX console, see Control Parameter on page 53. To manually turn
the lamp on or off:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the TEST menu. Press <Enter> to select.
3. Scroll to the LAMP menu. Press <Enter> to select.
4.
Scroll to ON to strike the lamp, or OFF to extinguish the lamp.
or
5. Press <Enter>.

Copying the Boot Code (BOOT)

New software uploaded to Studio Command fixtures may contain a new boot code which must
be copied to each BOOT section of the FlashROM. In this case, the LED displays a BOOT DIFF
error. To accept and store the new boot code:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the TEST menu. Press <Enter> to select.
3. Scroll to the BOOT option.
4. Press <Enter> to start the reboot. The fixture stores the new boot code, then
automatically homes.
Note: Do not remove power from the fixture while performing a boot copy.
Studio Command Series User Manual