Lubrication Guide - Sullair 12 Series Operator's Manual

40, 50, 60 and 75 hp industrial rotary screw air compressor
Table of Contents

Advertisement

Section 3
SPECIFICATIONS
SULLAIR SERIES 12 AND 16 SPECIFICATIONS (continued)
MOTOR: (50 Cycle Compressors)
Size
40-50-60 and 75 HP
Type
C-Flanged, Open Dripproof, 380V,
A.C., Three Phase, 50 Cycles
40ºC Maximum Ambient Temperature
Starter
460V Full Voltage Magnetic
Speed
1500 RPM
LUBRICATION GUIDE-STANDARD COMPRES-
SORS
Sullair standard compressors are filled with SRF
1/4000 fluid factory fill. MIXING OF OTHER FLU-
IDS WITHIN THE COMPRESSOR WILL VOID
ALL WARRANTIES.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particle level, corrosive gases or strong oxidiz-
ing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
14
40-50-60 and 75 HP
C-Flanged, Open Dripproof, 380V,
A.C., Three Phase, 50 Cycles
40ºC Maximum Ambient Temperature
460V Full Voltage Magnetic
1500 RPM
LUBRICATION GUIDE-24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which rarely needs to be changed. In the event a
change of fluid is required, use only Sullair 24KT
fluid. MIXING OF OTHER LUBRICANTS WITHIN
THE COMPRESSOR UNIT WILL VOID ALL WAR-
RANTIES!
Sullair recommends that a 24KT sample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with in-
structions and self-addressed container is to be
supplied by your Sullair Representative at start-up.
The user will receive analysis report with recom-
mendations.
APPLICATION GUIDE
Sullair encourages the user to participate in a oil
analysis program with the oil suppliers. This could
result in an oil change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.