Initial Start-Up Procedure; Subsequent Start-Up Procedure; Shutdown Procedure - Sullair LS-20S Operator's Manual And Parts List

Industrial air compressor
Table of Contents

Advertisement

Section 6
COMPRESSOR OPERATION
CONTROL OR INDICATOR
BLOWDOWN VALVE ASSEMBLY
THERMAL MIXING VALVE
FLUID STOP VALVE
SUMP SIGHT GLASS
SEPARATOR RETURN LINE SIGHT GLASSES
WATER PRESSURE SWITCH
DRAIN VALVES

5.3 INITIAL START-UP PROCEDURE

The following procedure should be used to make the
initial start--up of the compressor.
1. Read the preceding pages of this manual thor-
oughly.
2. Jog motor to check for correct rotation of fan (re-
fer to Section 2.6).
3. Be sure that all preparations and checks de-
scribed in the Installation Section have been
made.
4. Open the shut--off valve to the service line.
5. Check for possible leaks in piping.
7. Slowly close the shut--off valve to assure proper
nameplate pressure unload setting is correct.
The compressor will unload at nameplate pres-
sure. If adjustments are necessary, see Control
System Adjustments.
24
PURPOSE
Vents the sump vessel to atmosphere during unload-
ing and shutdown.
Bypasses fluid flow around the cooler until the former
reaches a temperature of 180_F (82_C). Useful for fast
warm--up during start. Maintains a minimum tempera-
ture of 180_F (82_C) during periods of low load or low
ambient temperatures.
Blocks the flow of fluid to the compressor during shut-
down, thus preventing the discharge of fluid through
the compressor inlet pipework.
Indicates level of lubricant in the sump. Located on the
sump side, it should show half--full (compressor
stopped) for proper fluid level.
Indicate fluid flow in the separator return lines. Large
flow should be visible during full load operation; little to
no flow during unloaded operation. Sluggish flow dur-
ing full load operation indicates the need to clean the
strainers fitted to the return lines.
De--energizes the starter, via the Supervisor, if the wa-
ter pressure falls below 10 psig (0.7 bar). This switch is
not adjustable. Used on water--cooled packages only.
Lubricant sump drain valve.
7. Observe the operating temperature. If the operat-
ing temperature exceeds 200_F (93_C), the
cooling system and installation environment
should be checked.
8. Open shut--off valve to the service line.
9. Reinspect the compressor for temperature and
leaks the following day.

5.4 SUBSEQUENT START-UP PROCEDURE

On subsequent start--ups, check that the proper
level is visible in the fluid sight glass and simply
press the START button. When the compressor is
running, observe the instrument panel and mainte-
nance indicators.

5.5 SHUTDOWN PROCEDURE

To shut the compressor down, simply press the
STOP button.