8 Power supply system SITOP PSU8600 redundant
8.2

Copying process tag types

The SITOP library contains the appropriate function modules and process tag
types for the different PSU8600 variants.
The function blocks of the used SITOP PSU8600 V1.4 with one output are
configured in the measuring point type "PSU86s14_CNX86_14". This contains a
driver block "Dr86s_14" and the monitoring block "PSU86s14". The blocks have
already been correctly interconnected with one another.
The Redundancy module PSE202U features a signaling contact connected with
the de-centralized peripherals. The required modules for the monitoring a digital
input signal are part of the process tag type "SITOP".
Proceed as follows:
1. Open the SITOP library "SITOP_APL_V3_2".
2. Copy the measuring point type "PSU86s14_CNX86_14" (1) and the measuring
point type "SITOP" into the folder "Measuring point types" of the master data
library.
Figure 8-6
Integration of a SITOP 24V power supply in PCS 7