·  Mouth to mouth resuscitation without a barrier device is not
recommended, as it will contaminate the airway.
·  Treat the simulator with the same precautions that would be used with
a
real
patient.

Cleaning

·  The simulator should be cleaned with a cloth dampened with diluted
liquid dish washing soap.
·  Remove all traces of any lubricant.
·  Do not clean with harsh abrasives.
·  Do not use povidone iodine on the simulator.
·  Dry thoroughly.
·  The simulator is "splash-proof" but not water-proof. Do not submerge
or allow water to enter the interior of the simulator.
Stoma and Breast Examination Insert Guidelines,
Warnings, and Maintenance
  · The stomas and breast inserts are constructed of material that
approximates tissue texture; therefore, use the same gentle techniques
as you would when working with a patient.
  · Always handle the stomas and inserts with clean hands.
  · Always palpate the breast using the fatty pads of the middle three
fingers.
  · Prevent items from resting or pressing against the stomas/breasts as
indentations will form on the pressure points. The stomas/breasts may
return to the normal shape after the pressure is relieved.
  · When removing the stomas, gently separate the stoma flange from the
torso, and do not apply force directly to the stoma tissue itself.
  · Place talcum powder on the stoma/breast surface to reduce tackiness.
Reapply talcum powder as needed.
  · Clean the stomas/breast using a mild solution of soap and water.
  · Apply talcum powder to return the surface to a skin-like feel and
appearance.
  · Always remove the stomas/breasts during transport.
  · Store the breast examination inserts facing down inside the protective
case when not in use.
  · Do not palpate the breast using fingernails
  · Do not clean the inserts with alcohol or aggressive solvents
  · Do not pack any sharp objects with the stomas/breast
  · Do not press the stomas/breast against soiled surfaces, ink, or
newsprint. The stoma/breast material is absorbent.
SUSIE®
S2000 |
User Guide