Summary of Contents for Gaumard PREMIE Blue S108.250

  • Page 1 PREMIE ™ Blue S108.250 is an interactive educational system developed ©2017 Gaumard Scientiic to assist a certiied instructor. It is not a substitute for a comprehensive All Rights Reserved understanding of the subject matter and not intended for clinical decision www.gaumard.com...
  • Page 3: Table Of Contents

    PREMIE™ Blue S108.250 | User Manual Contents End User License Agreement 1. Introduction 1.1 Speciications Premie™ Blue 1.2 Care and Maintenance General IV Arm Operating Conditions Storage Conditions Procedures Cleaning 2. Getting Started 2.1 Overview Airway Appearance Artiicial Respiration Circulation Simulator Venous Access 2.2 Terminology...
  • Page 4 PREMIE™ Blue S108.250 | User Manual 4.2 Circulation Palpable Pulses IV Access Directions for Use IV Maintenance 4.3 Intraosseous Access Directions for Use Replacing the Tibia Bones 4.4 Cyanosis 4.5 Umbilical Catheterization Directions for Use Heelstick 5. Using OMNI® 2 5.1 Main Screen Changing a Vital Sign 5.2 Hypoxia...
  • Page 5: End User License Agreement

    (including damages for loss of business proits, business interruption, loss of business information, and the like) arising out of the use or inability to use such product or related to this agreement even if Gaumard has been advised of the possibility of such damages.
  • Page 6 PREMIE™ Blue S108.250 | User Manual 6 | Introduction...
  • Page 7: Introduction

    General ·  Ball point pens, ink, and markers permanently stain the skin. ·  Do not wrap this or any other Gaumard product in newsprint. ·  Replacement parts are available from Gaumard Scientiic or from your Distributor IV Arm · ...
  • Page 8: Operating Conditions

    PREMIE™ Blue S108.250 | User Manual Operating Conditions   · The simulator will only power on when connected to the AC power supply.   · Operating temperature: 50°-95° F (10°-35° C)   · Humidity: 5%-95% (non-condensing) Storage Conditions Store Simulator in a cool, dry place. Extended storage above 85 degrees •...
  • Page 9: Getting Started

    PREMIE™ Blue S108.250 | User Manual 2. Getting Started 2.1 Overview • Powerful yet intuitive user controller and interface software • Resuscitation modeling • Quality CPR with measured and logged feedback Airway • Oral and nasal intubation • Use an ET tube or LMA •...
  • Page 10: Venous Access

    PREMIE™ Blue S108.250 | User Manual Venous Access • Patent umbilicus • Intraosseous access at tibia • IV training arm 2.2 Terminology Facilitator The person conducting the simulation; an instructor or lab staf member. Provider A person participating in the simulation as a healthcare provider. 4 | Equipment Setup...
  • Page 11: Equipment Setup

    PREMIE™ Blue S108.250 | User Manual 3. Equipment Setup 3.1 Overview Unpacking Lift the simulator from the soft blue case carefully with two hands. Remove the clear poly bag and lay him on a lat surface. WARNING: To avoid damage to the simulator, please store and ship it in the clear poly bag provided.
  • Page 12 PREMIE™ Blue S108.250 | User Manual A startup screen is shown while OMNI® 2 is detecting the simulator features. Follow the on-screen tutorial for a brief overview of the features of OMNI® 2. Move onto the next steps in the Tutorial by selecting “GOT IT”.
  • Page 13 PREMIE™ Blue S108.250 | User Manual After the tutorial, OMNI® 2 will automatically proceed to the Favorites page and establish a connection to Premie Blue. WARNING: Do not connect Premie Blue or OMNI® 2 to a computer, LAN network or unathorized diagnostic equipment.
  • Page 14: PremieĀ® Blue Features

    PREMIE™ Blue S108.250 | User Manual 4. Premie® Blue Features 4.1 Airway Management Pulmonary Ventilation Practice BVM techniques using an infant sized mask. Bilateral lung expansion is perceived with realistic chest rise. Efective CPR with Premie Blue and obtain feedback information via the OMNI®...
  • Page 15: Suction

    PREMIE™ Blue S108.250 | User Manual Suction Premie Blue can be used to simulate suction procedures. 4.2 Circulation Palpable Pulses Generate palpable umbilical pulses using the squeeze bulb. Connect the squeeze bulb to the port on the left side of the simulator. IV Access Premie Blue has IV access in the lower right arm that can be used for...
  • Page 16: Directions For Use

    PREMIE™ Blue S108.250 | User Manual Directions for Use Filling IV System Tube 1: illing Tube 2: drainage tube Place the end of the tube 2 into a drainage container and open the adjustable clamp. Drainage container not included in kit. Fill the dispensing syringe with luid.
  • Page 17: Maintenance

    PREMIE™ Blue S108.250 | User Manual WARNING: Use only Gaumard’s provided simulated blood. Any other simulated blood brand containing sugar or any additive may cause blockage and/or interruption of the vasculature system. Use a 25-27 gauge needle set. IV Maintenance Replacing the arm skin Gently pull the IV arm skin.
  • Page 18 PREMIE™ Blue S108.250 | User Manual Remove the screw and its socket from the joint. Gently pull out the lower arm until the black electrical con- nector is visible. Unfasten the connector by pressing on the clip. The male electrical connector resides in the upper arm.
  • Page 19: Intraosseous Access

    PREMIE™ Blue S108.250 | User Manual Attach the lower arm to the elbow joint. 10. Insert the screw socket into the elbow joint colser to the median plane of the simulator. 11. Place the screw into the other side of the elbow joint and fasten until the connection is secure.
  • Page 20: Directions For Use

    PREMIE™ Blue S108.250 | User Manual The tibia bones supplied with your simulator are made from hard plastic that can be pierced by an intraosseous needle. Once holes have been made in the tibia it can leak. We have minimized leakage by controlling luid pressure in the bone using inlet and drain valves.
  • Page 21: Replacing The Tibia Bones

    PREMIE™ Blue S108.250 | User Manual Perform IO exercises. When the training session is completed, open the drainage tube 2 adjustable clamp and drain the luid. If needed, use the dispensing syringe full with air to push remaining luid out the system.
  • Page 22 PREMIE™ Blue S108.250 | User Manual Pull out the tibia bone out of the leg. Insert the new tibia. The illing and drainage tubes are irst, followed by the bone. Re-attach tibia cover. Connect the syringe connector to the illing tube and the clamp to the draining tube.
  • Page 23: Cyanosis

    PREMIE™ Blue S108.250 | User Manual 4.4 Cyanosis Premie Blue features the SmartSkin in its forearms and lower legs to cause the skin to turn from a normal healthy color to a blue color indicative of pe- ripheral cyanosis. It also features the SmartSkin in the cheeks to indicate central cyanosis.
  • Page 24: Heelstick

    PREMIE™ Blue S108.250 | User Manual Place the end of the tube into a drainage container and open the adjustable clamp. Fill the syringe with luid. Connect the syringe to the port on the right side of the Premie Blue and push in luid. Allow the luid to low through the system and into the drainage container.
  • Page 25: Using Omni

    PREMIE™ Blue S108.250 | User Manual 5. Using OMNI® 2 5.1 Main Screen OMNI® 2 opens at the Favorites Page upon start up. Changing a Vital Sign Vital signs can be quickly changed from the Favorites Page or from the “Vitals”...
  • Page 26: Hypoxia

    PREMIE™ Blue S108.250 | User Manual 5.2 Hypoxia In order to simulate a hypoxic event, navigate to the Hypoxia Page. This model allows users to treat the emergency with ap- propriate airway and ventilation exercises. OMNI® 2 will detect ventilations automatically and will measure whether or not they meet or exceed documented CPR stan-...
  • Page 27: Cpr

    PREMIE™ Blue S108.250 | User Manual 5.3 CPR The CPR Page incorporated in the OMNI® 2 tablet was designed to help teach CPR by monitoring cadence and depth of cardiac compressions and airway ventilations in real time. WARNING: Do not perform mouth to mouth ventilation since the simulator airway can be diicult to clean afterwards...
  • Page 28: Actions

    PREMIE™ Blue S108.250 | User Manual Actions Buttons Function Begin and end a CPR session Reset a CPR session Activate an audible coach for training Virtually deibrillate the simulator Calibration Before running a CPR scenario, please make sure to calibrate the com- pressions.
  • Page 29 PREMIE™ Blue S108.250 | User Manual Select “Compression” once the calibration window appears. Adjust the Target compression depth with the +/- and tap “START” Follow the prompts to calibrate the target compression depth Using OMNI 2 | 23...
  • Page 30 PREMIE™ Blue S108.250 | User Manual Select “SAVE” to apply the changes. Tap “Start” to begin a CPR session. For more information about the CPR monitoring and reporting, refer to the OMNI® User Guide. 24 | Using OMNI 2...
  • Page 31: Virtual Monitor Setup (Optional)

    PREMIE™ Blue S108.250 | User Manual 6. Virtual Monitor Setup (Optional) A patient virtual monitor is an optional purchase with OMNI® 2. Follow the steps below in order to activate this feature: Connect the provided router to the wall. Tap the gear on the top right of the screen.
  • Page 32 PREMIE™ Blue S108.250 | User Manual Tap the gear on the top right of the screen. Select “Virtual Monitor”. Follow steps 9-10 if the activation code was not inputted. Verify that the serial num- ber corresponds to the manikin. 10. Input a valid activation code.
  • Page 33 13. On the monitor, connect to the same network as OMNI® 2. 14. Once connected to the WIFI, open the Gaumard Monitors software. 15. Tap the V on the top left and then select “Comm Setup”. 16. Verify that the IP address in the “Wireless Communication...
  • Page 34: Appendix

    PREMIE™ Blue S108.250 | User Manual 7. Appendix 7.1 Selected Parts List Contact Gaumard Scientiic for a complete list of consumables and re- placement parts and their prices. Item Type Code Artiicial Blood Concentrate Consumable S108.812 Lubricant Consumable S108.974 Arm Skin Replacement S108.813.L/M/D...
  • Page 35: Troubleshooting

    PREMIE™ Blue S108.250 | User Manual 7.2 Troubleshooting Communication/Power Issues Communication with the simulator cannot be established Controlling tablet is too far Minimize the distance between sim- away from simulator ulator and the tablet. Should not be over 10 meters away More than one device is paired Open Bluetooth Connection Setup.
  • Page 36: Warranty

    Gaumard at 14700 SW 136 Street, Miami, FL, 33196-5691 USA. If the necessary repairs to the Gaumard product are covered by this limited warranty, then the irst purchaser will pay only the incidental expenses associated with the repair, including any shipping, handling, and related costs for sending the product to Gaumard and for sending the product back to the irst purchaser.
  • Page 37 Gaumard®, ZOE®, Michelle®, Mike®, PEDI®, Susie Simon®, Susie®, Simon® Code Blue®, SIMA Models®, SIMA GYN/AID®, Virtual Instruments®, Codemaker®, Code Blue®, NOELLE®, Simulation Made Easy™, HAL®, eCPR™, Zack™, RITA™, Chloe™, Seatbelt Susie™, Krash Kids™, Premie™, UNI™, Omni®, Omni® 2, SmartSkin™ are trademarks of Gaumard Scientiic Company.

Table of Contents