THE INSTALLATION SPACE

*Finished Width
6-3/4"
Electrical
84 ±1/2"
Area
Finished
Opening
24"
5"
Water Supply
3-1/2"
*The finished cutout width must be:
35-1/2" (90.17 cm)for 36" models
41-1/2" (105.41 cm) for 42" models
47-1/2" (120.65 cm) for 48" models
Water And Electrical Locations
The opening must be prepared with the electrical
and the cold water supply located as shown.
31-1000450 Rev. 1
36" Models 12"
42" Models 18"
48" Models 20"
6-3/4"
75" From Floor
to Bottom
of Electrical
Area
5"
3-1/2"
The Cutout Depth Must Be 24" (60.96 cm)
The refrigerator will project forward, slightly beyond
adjacent cabinetry for standard installation.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall. Electrical must be located on the rear
wall as shown.
• The water line can enter the opening through the floor
or back wall. The water line should be 1/4" O.D. copper
tubing or SmartConnect
line and water connection location, long enough to
extend to the front of the refrigerator. Installation of
an easily accessible shut-off valve in the water line is
required.