PARAMETER
Pump Enable*
|AC_Pump_Enable_SpdM
|AC_Pump_Enable_SpdM_Bit0 [Bit 0]
0x3896 0x00
Regen Lower Enable*
Regen_Lower_Enable_SpdM
Regen_Lower_Enable_SpdM_Bit0
[Bit 0]
0x3877 0x00
* This parameter appears twice in the parameter menu structure. Changing the value of this parameter affects the same parameter in Speed Mode
Express.
PARAMETER
Max Speed
Max_Speed_TrqM
0x3021 0x00
Kp
Kp_TrqM
0x3023 0x00
Ki
Ki_TrqM
0x3025 0x00
Kd
Kd_TrqM
0x3836 0x00
4 — PROGRAMMABLE PARAMETERS
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017
1- SPEED MODE — PUMP PARAMETERS
ALLOWABLE RANGE
On / Off
This parameter should be programmed On to operate a pump motor
rather than a vehicle drive motor. Speed controller responsiveness and
On / Off
stability are enhanced.
On / Off
This parameter works together with Pump Enable as follows:
On / Off
1) When Pump Enable = On and Regen Lower Enable = On, the pump
2) When Pump Enable = On and Regen Lower Enable = Off, the pump
3) When Pump Enable = Off, the Regen Lower Enable parameter has no
2 – TORQUE MODE — SPEED LIMITER MENU
ALLOWABLE RANGE
500 – 8000 rpm
Defines the maximum allowed motor rpm for torque control mode
(independent of throttle position). In torque control mode, full throttle
500 – 8000
requests 100% of the available torque. Partially-applied throttle is scaled
proportionately; e.g., 40% applied throttle corresponds to a request for 40%
of the available torque.
NOTE: The maximum motor rpm is subject to the constraints on
0 – 100%
Determines how aggressively the speed controller attempts to limit the speed
of the motor to Max Speed. Larger values provide tighter control.
0 – 8192
If Kp is set too high, you may experience oscillations as the controller tries to
control speed. Setting Kp too low may result in a top speed much higher than
Max Speed.
5 – 100%
The integral term (Ki) forces zero steady state error, so the motor speed will
be limited to Max Speed. Larger values provide faster control.
50 – 1000
If the gain is set too high, you may experience oscillations as the controller
tries to limit speed. If it is set too low, it may take a long time for the motor to
approach Max Speed from overspeed.
0 – 100%
Provides damping as the vehicle approaches top speed, thereby reducing
overshoot. If Kd is set too high, the vehicle may take too long to reach top
0 – 8192
speed. If Kd is set too low, the vehicle may overshoot top speed, especially
when traveling downhill.
DESCRIPTION
motor can turn in both the forward and the reverse direction. In this
case, the pump can be used as the Lower function (reverse). The
pump motor, when "driven in reverse by a load" will also regen current
in a similar fashion to a drive-motor regenerative braking.
motor can turn only in the forward direction. In this case, a hydraulic
valve is typically used for the Lower function.
effect on the control system.
DESCRIPTION
page
24.