Curtis 1232E Manual page 128

Enhanced ac controllers for induction motors and surface permanent magnet motors
Hide thumbs Also See for 1232E:
Table of Contents

Advertisement

Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017
START_PUMP( )
This function is used to turn on the pump lift contactor (pin 4). If the parameter Drivers » Driver3
» Contactor Enable = On (VCL HydraulicContactorEnable bit variable = On), the VCL function
Start_Pump() will turn on the pump lift contactor (Driver 3).
When HydraulicContactorEnable = On and neither Start_Pump() nor Stop_ Pump() has been called,
the pump lift contactor is Off.
STOP_PUMP( )
This function is used to turn off the pump lift contactor (pin 4). If the parameter Drivers » Driver3
» Contactor Enable = On (VCL HydraulicContactorEnable bit variable = On), the VCL function
Start_Pump() will turn off the pump lift contactor (Driver 3).
When HydraulicContactorEnable = On and neither Start_Pump() nor Stop_ Pump() has been called,
the pump lift contactor is Off.
pg. 124
Syntax:
Start_Pump()
Parameters:
None.
Returns:
0 – Pump start function not enabled.
1 – Pump start function successfully enabled.
Error Codes:
None.
Example:
Start_Pump()
This will turn on the pump lift contactor.
Syntax:
Stop_Pump()
Parameters:
None.
Returns:
0 – Pump stop function not enabled.
1 – Pump stop function successfully enabled.
Error Codes:
None.
Example:
Stop_Pump()
This will turn off the pump lift contactor.
10 — VEHICLE CONTROL LANGUAGE (VCL)
Return to TOC