- 4 - MAINTENANCE

4.1 MAINTENANCE AND CLEANING THE UNIT

• Make sure the area below the installation place is free from unwanted persons during setup.
• Switch off the unit, unplug the main cable and wait until the unit has cooled down.
• All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
• Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
• The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
• It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or
other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the
main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe
the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.

4.2 FUSE REPLACEMENT

1. Disconnect this product from the power outlet.
2. Using a screwdriver, unscrew the fuse holder cap from the housing.
3. Remove the blown fuse and replace with a good fuse of the same type and rating
(250V/T2A).
4. Screw the fuse holder cap back in place and reconnect power.

4.3 TROUBLESHOOTING

Problems
Fixture does not light up
General low light intensity
Fixture does not power up
Fixture does not respond to DMX
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
STUDIOCOB TU-DY
Possible causes
No mains supply
Dimmer fader set to 0
All color faders set to 0
Faulty LED
Faulty LED board
Dirty lens assembly
Misaligned lens assembly
No power
Loose or damaged power cord
Faulty internal power supply
Wrong DMX addressing
Damaged DMX cables
Bouncing signals
Checks and remedies
Check the power supply voltage
Increase the value of the dimmer channels
Increase the value of the color channels
Replace the LED board
Replace the LED board
Clean the fixture regularly
Install lens assembly properly
Check for power on power outlet
Check power cord
Replace internal power supply
Check control panel and unit addressing
Check DMX cables
Install terminator as suggested