6.1
Both Sides Adjustment
% Write down the measured values so that you do not forget them.
8
Press [a] to [d] of each point, and enter the adjustment value using the keypad, [,], or [+] on the screen.
% If the printing position is misaligned to the minus (-) side, enter a positive value (+). If the printing
position is misaligned to the plus (+) side, enter a negative value (-).
% To reset a numeric value, press [Clear].
% To switch the positive sign (+) and negative sign (-), press [+/-].
9
When entry processing is completed, press
[Adjustment Start].
The entered adjustment values are applied.
If [Back Side Magnification Adjustment] is set to
[OFF], the value of [d] (adjustment value of the
transverse magnification (Horizontal) on the
back side) is not applied.
10
Press Start on the control panel.
A test chart is printed out.