Graco Spindl-Gard 24B219 Instructions Manual

Graco Spindl-Gard 24B219 Instructions Manual

High speed lubrication system with electric pump

Advertisement

Quick Links

Instructions
High Speed Spindl-Gard
Lubrication System with
Electric Pump
For applying a constant quantity of oil directly to rotating bearing elements that operate at
speeds greater than 250,000 DN. For professional use only.
Models: Page 2
320 psi (2.2 MPa, 22 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual before using the equipment. Save
these instructions.
Components:
Electric motor driven pump
0.8 gallon (3 liter) plastic reservoir
Air/oil dispensing module
Optional programmable timer/controller
313444E
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spindl-Gard 24B219 and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco Spindl-Gard 24B219

  • Page 1 Instructions ™ High Speed Spindl-Gard Lubrication System with 313444E Electric Pump For applying a constant quantity of oil directly to rotating bearing elements that operate at speeds greater than 250,000 DN. For professional use only. Models: Page 2 320 psi (2.2 MPa, 22 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual before using the equipment.
  • Page 2 Spindl-Gard with Electric Pump Models Spindl-Gard with Electric Pump Models Outputs from Inlet to Controller End CC/Stroke Option Voltage Number of Outlets (cu in./stroke) Model 24B219 24H681 24R127 24V204 24V531 258295 258301 258347 25A202 25A209 564445 25C264 25C265 26C419 26C521 313444E...
  • Page 3 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 4: Component Identification

    Component Identification Component Identification C D E NOTE: Reference letters are used throughout the instructions on the following pages. Refer back to this page as needed. Purge Plug 1/4-18 Air Regulator Inlet, NSPF Manual Run Reset Button Air/Oil Delivery Line Pump ON LED AIr Flow Adjustment Screw Power ON LED...
  • Page 5: Installation

    Installation Installation NOTE: Reference letters used throughout these instruc- Power leads to their respective terminals within the tions refer to the reference letter provided on the Com- enclosure. ponent Identification page 4. Wiring Diagram: 115 VAC & 230 VAC Units •...
  • Page 6: Pneumatic Connections

    Installation Pneumatic Connections Timer Models Only 5. Connect input power leads to the input terminal block (Terminals 4 and 6) (F . 2). Pressure Relief Procedure 1. Loosen the purge plug (A) on the air/oil mixing block assembly (K). 2. Press the manual run button (B) until oil flows out of the port.
  • Page 7 The possible time choices for both the Pause and Plugging a Lubrication Point Work Times are shown on page 8. To plug an air/oil outlet, Graco Plug Part No. 555456 must be installed in the piston distributor port on top of NOTE: the air/oil mixing block.
  • Page 8 Installation Dip Switch Settings: Models With Timers Pause (off) Time (F . 2 and F . 3) Prelube (F . 2 and F . 3) The Pause (off) Time is set using dip switches DS3 and J1 is used to Yes or No. When set to Yes, the lube cycle DS1 to select the time to deliver the required lube vol- will immediately power up.
  • Page 9 Installation Controller Settings: Models With Timers Pause (off) Time (F . 3) Set the Pause (off) Time to between 2 minutes and 20 minutes to deliver the required lube volume per hour. NOTE: Do not exceed 20 minutes Pause (off) time. Monitor Time (F .
  • Page 10: Operation

    Operation Operation Theory of Operation 3. Verify oil output from each of the air/oil mixing blocks. Air is constantly being applied to the air/oil blocks. After a preset Pause (off) Time, the controller activates the NOTE: This step also ensures that the inside of the pump.
  • Page 11 Parts Parts 14, 25 ti128633 313444E...
  • Page 12 Parts Part No. Description Part No. Description 563130 BLOCK, Spindl-Gard, 0.0015 PUMP, EO-3 motor/timer 115V model 24B219 562850 (models 24B219, 258301, 24R127, 24V204, 25C264 and 258347) model 258347 PUMP, EO-3 24V, with timer (mod- model 25C264 564254 els 258295 and 564445) model 25C265 PUMP, EO-3 230V, without timer, 563131 BLOCK, Spindl-Gard, 0.0030...
  • Page 13: Technical Specifications

    Technical Specifications Technical Specifications ™ High Speed Spindl-Gard Lubrication System with Electric Pump Metric Pressure Readings Pressure Relief Setting 350 psi 3.4 MPa, 34 bar Output Block Regulator 30 - 60 psi 0.207 - 0.414 MPa, 2.07 - 4.14 bar Pressure Switch Set Points Air (N.C.) 25 psi nonadjustable...
  • Page 14: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.