5.10.3.3 Display mode for Up/Down welding torch with one-digit 7-segment display (P3)

Normal display:
Program mode: Program number
Up/down operation: Welding power (0=minimum current/9=maximum current)
Toggling display:
Program mode: Program number and welding procedure (P=pulse/n=not pulse) are toggled
Up/down operation: Welding power (0=minimum current/9=maximum current) and symbol for up/down
operation are toggled

5.10.3.4 Program limit (P4)

Program selection can be limited with the special parameter P4.
The setting is adopted for all JOBs.
Program selection depends on the position of the "welding torch function" changeover
switch > see 4.3 chapter.
Programs can only be switched when the changeover switch is in the "program" position.
Programs can be switched by means of a connected remote control or special welding torch.
If a special welding torch or a remote control is not connected, it is only possible to switch programs by
means of the "arc length correction/select welding program" rotary dial > see 4.4 chapter.

5.10.3.5 Special cycle in the operating modes special latched and non-latched (P5)

With the special sequence activated, the start of the welding process changes as follows:
Sequence for special non-latched mode/special latched mode:
Start program "P
Main program "P
Sequence for special non-latched mode/special latched mode with custom sequence activated:
Start program "P
Reduced main program "P
Main program "P
Enabling special JOBs SP1 to SP3 (P6)
Phoenix Expert machine series:
The welding task is set at the power source control; refer to the relevant system documentation.
If required, the predefined special welding tasks SP1 = JOB 129 / SP2 = JOB130 / SP3 = JOB 131 only
can be selected at the wire feeder control. The special JOBs are selected by pressing the welding task
selection push-button for a longer period. The special JOBs are switched by pressing the push-button
briefly.
The JOB changeover is blocked if the key switch is in the "0" position.
This block can be cancelled for the special JOBs (SP1 - SP3).
099-005507-EW501
13.09.2018
"
START
"
A
"
START
"
B
"
A
Design and function
Special parameters (advanced settings)
79

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the drive 4X IC D HP and is the answer not in the manual?

Questions and answers

Table of Contents