Electrode - Garland HEEGM48CL Service Manual

High efficiency radiant char-broiler
Table of Contents

Advertisement

6 COMPONENTS

6.8 Electrode

All burners are equipped with continuous electronic spark electrodes to ensure flame is on at all
times during operation.
Continuous sparking is intended to remain energized until its corresponding ignition control
module senses flame current. Electrical spark generation is then shut off until flame current is no
longer sensed. Refer to the wiring diagrams for proper ignition wire connections to the ignition
module.
Spark gap: min 0.125"(1/8"), and max 0.160"(5/32").
Visual inspection is often sufficient to check for a faulty electrode. Check for bent, damaged
electrodes or cracked ceramics on the electrodes.
6.8.1 Removing & Installing an Electrode
WARNING
Disconnect electrical power from the unit.
IMPORTANT You CANNOT loosen the electrodes from
i
the burner side. Remove the valve panel and the wire
channel cover to gain access to the electrodes.
IMPORTANT If there are metal wire ties on the silicone
i
sleeve, ensure to keep the metal ties away from the
electrodes to avoid shorting. See illustration below.
To replace an electrode:
5a
Some components are not shown.
1.
WARNING: Disconnect electrical power from the unit.
2. Remove the knobs and the valve panel (see "6.2 Valve Panel").
3. Loosen the screws for the grease chute (at the bottom of the chute) and drop the grease chute
down.
4. Remove the screws at the front of the wire channel to take the cover off.
(CONT.)
4
7
Screwdriver
Page 24 | HEEGM Service Manual part# 4532502 (Rev 0)
Metal Wire Tie,
5
or Silicone Rubber Tape
7
Silicone Sleeve

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heegm60clHeegm36clHeegm24cl

Table of Contents