RCD check (GFCI)
AC short-circuit
protection
AC surge protection
Interfaces
Display
USB
RS485
WIFI
GPRS
4G
General Data
Dimensions (W / H / D)
Weight
Operating temperature
range
Noise emission (typical)
Relative humidity
Highest Altitude
Self-Consumption night
Topology
Cooling concept
Environmental
Protection Rating
Warranty:
Certificates and
approvals
Safety /EMC
Model
Input data
Max. recommended PV
power(for module STC)
Max. DC voltage
Start voltage
Nominal voltage
MPP voltage range
Full load MPP voltage
Max. input current per
EN 61000-3, EN 61000-6, EN/IEC 62109-1, EN/IEC 62109-2,
MAC 50KTL3-X MV
65000W
700V
50A/37.5A/37.5A
YES
YES
YES(Class II)
OLED+LED/WIFI+APP
YES
YES
Option
Option
Option
680*508*281 mm
52kg
–25° C ... +60° C (derating over 45° C)
≤55dB(A)
0~100%
4000m
< 1W
Transformerless
Fan cool
IP65
5 years/10years(Option)
IEC 60529
MAC 60KTL3-X
MAC 66KTL3-X
MV
78000W
1100V
250V
700V
200V-1000V
650V-850V
50A/50A/50A
54 / 57
编号:GR-UM-C -00
MAC 70KTL3-X
MV
85800W
700V
50A/50A/50A
50A/50A/50A
MV
91000W
700V