7.2.4 Shutdown Mode
When the sunlight is weak or no light, inverter will stop working automatically. When it is off, inverter will not consume
gird power or PV module.At the same time, the OLED lamp and LED display of the inverter will be extinguished.
Note: When PV string DC voltage is too low(≤150VDC) ,inverter will be off.
7.3 OLED Display and Touch Buttons
The OLED display can display the operating status of the inverter and various parameter information. The touch panel can
be used to switch the display interface of the inverter and set the inverter parameters.。
7.3.1 Boot Display
When the inverter is turned on, the OLED display interface is as follows:
Touch mode
single
Two consecutive times
Three consecutive times
Long press 5S
Growatt
PV inverter
CUTDOWN
30S
Connect OK
Power
XXXXw
Etoday
XXXkWh
Etotal
XXXXw
definition
Switch or current
number plus 1
Go to Settings & OK
Return to the previous
display interface
Current data is zeroed
More info
Set
Parameter
PV2
XXXvXXXXw
PV1
XXXvXXXXw
Grid
XXXvXXXHz
28 / 57