9.2.2 Error

Errors codes identify a possible equipment failure, fault or incorrect inverter setting or configuration, any or all attempts to
correct or clear a fault must be performed by qualified personnel.
Typically, the error code can be cleared once the cause or fault is removed.
Some of error code as table shows below, may indicate a fatal error and require you to contact the supplier or Growatt for
help.
Error
Description
Code
AFCI Fault
Error 200
Leakage current too high.
Error 201
The DC input voltage is
exceeding the maximum
Error 202
tolerable value.
PV Isolation Low
Error 203
AC V Outrange
Error 300
U disk over-current
protection
Fan function abnormal
Meter abnormal
Optimizer and inverter
communication is
abnormal
EEPROM abnormal.
DSP and COM firmware
version unmatch
NTCBroken
1: unplug the U disk
2: Re-access U disk after shutdown
3.If the error message still exists, contact manufacturer.
1.After shutdown,Check the fan connection.
2. replace the fan.
3. If the error message still exists, contact manufacturer.
1: Check if the meter is on
2: Check the machine and the meter connection is normal
1. Check if the optimizer is on.
2. Check whether the connection between the optimizer and
the inverter is normal.
1.Restart inverter.
2.If error message still exists,contact manufacturer.
1.Check the firmware version.
2.If error message still exists,contact manufacturer.
1.Restart inverter
2.If error message still exists, contact manufacturer.
Suggestion
1.After shutdown,Check the panel terminal.
2.Restart inverter.
3.If error message still exists,contact manufacturer.
1.Restart inverter.
2.If error message still exists,contact manufacturer.
1.Immediately disconnect the DC switch and check the
voltage
2:.If the fault code still exists after the normal voltage is
restored, contact manufacturer
1.After shutdown,Check if panel enclosure ground
properly.
2.If error message still exists,contact manufacturer.
1.Check grid voltage.
2.If the error message still exists despite the grid voltage
being within the tolerable range, contact
51 / 57
编号:GR-UM-C -00