FPZ SCL K05 MS-MOR Instructions Manual page 45

Lateral channel blowers-exhausters
Hide thumbs Also See for SCL K05 MS-MOR:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 29
Fluid leakage
Intervention of one
or more sensors
ENERGOEKONOM spol. s r.o., Wolkerova 433, CZ-250 82 Úvaly, Czech Republic, Tel.: +420 281 981 055, info@energoekonom.cz, www.energoekonom.cz
G
The impeller has accumulated deposits.
G
Unit fixed without vibration dampers.
F
Rigid connection to the system
G
Faulty bearing on blower side or motor side.
G
Faulty gaskets on the silencer.
G
Faulty gaskets on the cover.
G
Leaks from mechanical seals
F
False alarms
Pressure switch or vacuum switch
G
intervention
Overheating with temperature sensor
G
intervention
Excessive vibration with vibration sensor
G
intervention
Have the unit cleaned inside by FPZ After-Sales Service.
Have the unit secured with vibration dampers by the
Technician.
Have flexible sleeves installed between the unit and the
pipes by the Technician.
Have the bearing replaced by FPZ After-Sales Service.
Have the gaskets checked and, if necessary, replaced by
FPZ After-Sales Service.
Have the gaskets checked and, if necessary, replaced by
FPZ After-Sales Service.
Have the seals checked and, if necessary, replaced by
FPZ After-Sales Service.
Check the alarm and shutdown system.
Check the system and have the machine
inspected/repaired by FPZ After-Sales Service