Troubleshooting - Leggett & Platt BRIO B-120 Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

If the adjustable base fails to operate, investigate the symptoms and possible solutions
provided in the chart below:
SYMPTOM
Remote control illuminates and appears to be
operable, but will not activate base.
No features of the base will activate.
Remote control will not illuminate.
Head or foot section will elevate, but will not
return to the horizontal (flat) position.
12

TROUBLESHOOTING

SOLUTION
• Verify power cord is plugged into a working, grounded
electrical outlet. A grounded, electrical surge protection
device is recommended. Test outlet by plugging in
another working appliance.
• If the base was operated over the rated duty cycle,
thermal switch opens. Wait 30 minutes before trying
to operate the base. Once the base resumes normal
operation, do not exceed the duty cycle.
• Program the remote control (see Remote Control
Programming section of this manual for programming
procedures).
• Unplug power cord, wait 30 seconds and plug in to
reset electronic components.
• Electrical circuit breaker may be tripped. Check
electrical service breaker box to verify.
• Defective surge protection device or electrical outlet.
Test outlet by plugging in another working appliance.
• Replace batteries in the remote control.
• Base mechanism may be obstructed. Elevate base and
check for obstruction. Remove obstruction.
• Head section may be too close to the wall.
• Headboard (if used) may be too close the edge of the
mattress. Verify a 1.5" (38.1mm) to 2" (50.8mm)
distance between headboard brackets and mattress.
Adjust if required.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRIO B-120 and is the answer not in the manual?

Table of Contents